497163
25
Zoom out
Zoom in
Previous page
1/142
Next page
23
4.2 Assembling the Pressure Vessel and the Pressure Vessel Lid
Stand with both feet on the kick loops
12
.
Lift the pressure vessel
1
and turn it clockwise until the mantle handles
16
are over the kick loops
12
.
Remove the transport protective cap
18
from the fi lter cartridge.
Check that the O-ring seal of the fi lter cartridge
2
is correctly seated in the
groove and also check for dirt and damage.
Note: lubricant at the factory.
Stand on the kick loops
12
with both feet and place the pressure vessel lid
3
on the pressure vessel
1
. The position of the arrow marking on the lid
handle
20
must match the “INSERT” groove.
Press the pressure vessel lid
3
down and turn clockwise until the lock
15
engages.
4.3 Assembly of Inlet and Outlet Hoses
Note: The inlet and outlet hoses are not included in the standard scope of delivery. The use of
BRITA hose sets is recommended (Chapter 13).
Fit inlet hose
6
at the inlet of the connector head
4
and outlet hose
10
at the outlet of the con-
nector head
4
.
Note: Inlet “IN” and outlet “OUT” of the connector head
4
are equipped with O-rings as
seals, therefore no additional fl at seals may be used here. Check that the O-rings are seated
correctly.
!
Caution: The max. tightening torque at the 1" and 3/4" connections must not exceed 15 Nm!
Only hose connections with fl at seals may be used. Hoses with conical screwed connections dam-
age the fi lter head connections and invalidate any guarantee claims. Only hoses that comply with
DVGW-W 543 may be used to connect the device.
Before assembly, note the direction of fl ow on the upper side of the fi lter head, “IN” = water inlet,
“OUT” = water outlet. Prior to installation, note installation dimensions and operating position
(Chapter 12). If no original hoses are used, the 1"3/4"
17
adapter supplied must be used to ensure
the return valve is sealed correctly (pre- tted in the water inlet).
5 Commissioning a New Filter
5.1 Bypass Setting for Filter Systems without and with Measuring and Display Unit
Identify the local carbonate hardness in German hardness °dH (BRITA nomenclature °KH) using
the enclosed carbonate hardness test.
Check the bypass setting on the bypass screw
19
.
Note: The bypass has been set to Position 1 in the factory, and must be changed to suit the
local carbonate hardness and the application (Chapter 7).
5.2 Commissioning the Filter Systems with Measuring and Display Unit
Representation in operating mode
Local Carbonate
Hardness Set
Type/
By-Pass Proportion
Date Field: Installation or
last fi lter change date
Available residual
capacity in litres
Bar Display
Flow Symbol
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brita PURITY 1200 Steam at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brita PURITY 1200 Steam in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 3,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info