784734
74
Zoom out
Zoom in
Previous page
1/80
Next page
74
7. The console will stay in AP mode for you to check the rmware version and all the current
setting. Simply press and hold [ SENSOR / WI-FI ] key for 6 seconds to exit AP mode.
IMPORTANT NOTE:
- Please keep connecting the power during the rmware update process.
- Please make sure your PC/Mac's WI-FI connection is stable.
- When the update process start, do not operate the PC/Mac and console until the update nished.
- During rmware update the console will stop upload data to the cloud server. It will reconnect to your WI-FI
router and upload the data again once the rmware update succeed. If the console cannot connect to your
router, please enter the SETUP page to setup again.
- After the rmware update, If the setup informations are missing, please input the setup information again.
- Firmware update process have potential risk, which cannot guarantee 100% success. If the update fail,
please redo the above step to update again.
8.2 BATTERY REPLACEMENT
When low battery indicator or is
displayed near the antenna icon of
the sensor(s), it indicates that the
outdoor 7-IN-1 sensor and/or current
channel sensor(s) battery power is low
respectively. Please replace with new
batteries.
8.2.1 RE-PAIRING THE SENSOR(S) MANUALLY
Whenever you changed the batteries of the 7-in-1 weather sensor array or other additional
sensors, re-synchronization must be done manually.
1. Change all the batteries to new ones in the low battery sensor(s).
2. Press [ SENSOR / WI-FI ] key on the console to enter sensor synchronization mode (as
indicated by the ashing antenna ).
8.3 RESET AND FACTORY RESET
To reset the console and start again, press the [ RESET ] key once or remove the backup battery
and then unplug the adapter.
To resume factory settings and remove all data, press and hold the [ RESET ] key for 6 seconds.
8.4 WIRELESS 7-IN-1 SENSOR ARRAY MAINTENANCE
REPLACE THE WIND VANE
Unscrew and remove the wind
vane for replacement
REPLACE THE WIND CUP
1. Unscrew and remove the
top cap
2. Remove the wind cup for
replacement
CLEANING THE THERMO-
HYGRO SENSOR
3.
Remove the 2 screws at the
bottom of the radiation shield.
4.
Gently pull out the shield.
5. Carefully remove any dirt or
insects on the sensor (do not let
the sensors inside get wet).
6.
Clean the shield with water to
remove any dirt or insects.
7. Install all the parts back when
they are clean and fully dried.
CLEANING THE RAIN COLLECTOR
1. Rotate the rain collector by turning it
30°anti-clockwise.
2. Gently remove the rain collector.
3. Clean and remove any debris or
insects.
4. Install the collector when it is clean
and fully dried.
CLEANING THE UV SENSOR AND
CALIBRATION
For precision UV measurement,
gentle clean the UV sensor cover
lens with damp micro-ber cloth.
Over time, the UV sensor will
naturally degrade. The UV sensor
can be calibrated with a utility grade
UV meter, please refer to Calibration
section in previous page for about
the UV sensor calibration.
74


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bresser 7003220 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bresser 7003220 in the language / languages: English, German as an attachment in your email.

The manual is 12.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bresser 7003220

Bresser 7003220 User Manual - Dutch - 24 pages

Bresser 7003220 User Manual - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info