729991
11
Zoom out
Zoom in
Previous page
1/20
Next page
11 / 20
4. Attach the windmeter/rain gauge and the mounting shoe to the mounting tube with the fixing
screws through the drill holes.
5. Attach the mounting shoe to a horizontally and vertically aligned pole or a wall with the enclosed
mounting material in at least 2 meters height.
6. Remove the battery compartment cover of the thermo-hygrosensor.
7. Insert the modular plug on the other end of the cable into the modular socket of the thermo-hygro
sensor.
CAUTION!Before inserting or removing the modular plug, press down the locking lug!
8. Mount the thermo-hygrosensor below the windmeter/rain gauge.
12 Automatic time setting
After the power supply was established, the clock will automatically search for the radio signal. The
clock will automatically search for the radio signal.
If the radio signal is received correctly, the date and time will be set automatically and the radio control
signal icon turns on.
If the clock fails to receive the time signal, go ahead with the following steps:
1. Press DOWN/RAIN HISTORY button and UP/RCC/ALARM button for approx. 2 seconds to re-initi-
ate radio signal reception.
2. If the device is still not receiving the signal, the time must be set manually.
Read the detailed manual for more information about manual time setting and other user defined set-
tings (see download information on page 2).
13 Manual time setting and other user defined
settings
1. In normal display mode, press MODE/SET button for approx. 3 seconds to switch to settings
mode.
2. Digits to be set are flashing.
3. Press DOWN/RAIN HISTORY button or UP/RCC/ALARM button to change the value.
4. Press the MODE/SET button to confirm the setting and move to the next setting.
5. Settings order: 12/24 hours mode > RCC on/off > time zone (-12 to +12 hours) > hours > minutes
> seconds > year > month > day > language > temperature unit > barometric pressure unit > wind
speed unit > precipitation unit > wind direction
6. Finally press MODE/SET button to save the settings and exit settings mode.
14 Setting the wind direction
To adjust the wind direction, proceed as follows:
1. Press the MODE/SET button for approx. 3 seconds to enter the settings mode.
2. Press the MODE/SET button repeatedly until the wind direction setting is shown in the display at
the end (all directions flash).
3. Align the wind vane with the wind turbine in a northerly direction (tip points north).
4. Press the UP/RCC/ALARM or DOWN/RAIN HISTORY button to set the wind direction indicator on
the display to North.
5. Press the MODE/SET button to confirm the setting.
15 Time zone setting
To set a different time zone, proceed as follows:
11


Need help? Post your question in this forum.

Forumrules
1

Forum

bresser-7002420-climatemp-xxl

Reset search

  • Windrichtung lässt sich nicht einstellen. Beim Bestätigen geht die Anzeige immer zurück auf Süd. Was kann ich tun? Submitted on 16-12-2022 at 11:52

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bresser 7002420 ClimaTemp XXL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bresser 7002420 ClimaTemp XXL in the language / languages: English as an attachment in your email.

The manual is 3,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bresser 7002420 ClimaTemp XXL

Bresser 7002420 ClimaTemp XXL User Manual - German - 16 pages

Bresser 7002420 ClimaTemp XXL User Manual - Dutch - 20 pages

Bresser 7002420 ClimaTemp XXL User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info