545966
11
Zoom out
Zoom in
Previous page
1/16
Next page
GB
ECopyright Bravilor Bonamat B.V.
7
5.3.1.2 Chiller (Type II)
1. Close the water tap.
2. Use button 3 to draw off the CO
2
reservoir until only CO
2
gas escapes (± 2,5 l water).
3. Fill the cleaning cartridge with the two bottles of detergent.
4. Connect the cleaning cartridge to the Chiller.
5. Turn the water tap open.
6. Use button 2 to draw off approximately 0.25 liters of water.
7. Wait for about 30 minutes, the Chiller will now fill with the cleaning agent.
8. Remove the cleaning cartridge and empty the water present.
9. Use the spray bottle to clean the outlet, during the filling process.
10. Close the water tap.
11. Use button 3 to draw off the CO
2
reservoir until only CO
2
gas escapes (± 2,5 l water).
12. Turn the water tap open.
13. Use button 2 to draw off approximately 1 liters of water.
14. The Chiller fills up again and after approx. 20 minutes ready for use.
15. Use button 3 to draw off the CO
2
reservoir until only CO
2
gas escapes (± 2,5 l water).
16. If a water filter is connected it should also be replaced now (see § 3.2.3).
17. Reset the timer for cleaning (see § 6.1.2).
The device is ready for use.
TIP
Ensure that there is always at least one spare water filter in stock.
Clean the ventilator and the outside of the condenser every year (if necessary with a vacuum
cleaner).
CAUTION!
The remaining maintenance activities are strictly reserved for specially trained service engineers
for coldwater systems.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bravilor Bonamat Chiller at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bravilor Bonamat Chiller in the language / languages: English as an attachment in your email.

The manual is 0,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bravilor Bonamat Chiller

Bravilor Bonamat Chiller User Manual - German - 16 pages

Bravilor Bonamat Chiller User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info