672104
7
Zoom out
Zoom in
Previous page
1/79
Next page
12 13
Storage and cleaning
Keep the unit in the storage case when not in use. Clean the product with a soft, slightly
damp cloth. Do not wet the cu or attempt to clean the cu with water. Do not wash
or dry clean the cu. Do not store the product in a place exposed to direct sunlight or
high humidity. Remove the batteries if the unit will not be used for 3 months or longer.
Always replace all of the batteries with new ones at the same time.
Specifications
Model: BPW4100
Operation principle: Oscillometric method
Display: Liquid crystal display
Measuring range: 0-280mmHg (cu pressure)
Blood pressure measurement: Systolic pressure: 60-280mmHg
Diastolic pressure: 30-250mmHg
Pulse rate: 40-180/min
Laboratory accuracy: Cu pressure: ±3mmHg
Pulse rate: ±5%
Ination: Automatic, soft adapted to blood pressure
Power supply: 2 batteries, type LR03(AAA)
Electric shock protection: Internal power supply appliance type BF
Operating environment: Temperature +10 °C ~ +40 °C
Humidity 15 ~ 85%RH (noncondensing)
Atmospheric pressure 105 kPa ~ 80 kPa
Transport and Temperature -20 °C ~ +60 °C
storage environment Humidity 15 ~ 85%RH (noncondensing)
Atmospheric pressure 105 kPa ~ 80 kPa
Cu: Suitable for wrist circumference of 13.5 to 21.5cm
Accessories: Batteries(2*AAA)
If device is not used within specied temperature and humidity ranges the technical
accuracy can not be ensured.
What to do if…
Problem Reason Solution
Battery icon is ashing Batteries are at.
Memory readings can be
called up, but measure-
ments are not possible.
Insert new batteries.
Err 1 Cu is not wrapped on
the wrist well (too loose).
Rewrap the cu tighter
on the wrist.
Err 2 Arm moved during
ination measurement.
Systolic pressure is
above 280mmHg
Please do not move arm
or speak when you take a
measurement.
No display No information on the
display screen.
Check the battery
installation for proper
installation of the
batteries’ polarities
Measurements appear
too high or too low
Blood pressure varies
constantly during the
day. Many factors such
as stress, time of day,
talking, coughing, laugh-
ing, moving etc. when
measuring will inuence
the reading.
Please read “key rules for
accurate blood pressure
measurements” and
“taking a measurement”
Prior to measurement,
the positioning system
(A) on the display does
not work.
Positioning system (A) is
deactivated.
Refer to the chapter
«select mode» to activate
the positioning system
(A).
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Braun BPW 4100 VitalScan at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Braun BPW 4100 VitalScan in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 8,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info