Turning off
Press the on/o button to turn the product o, otherwise the
product will turn o automatically after 2 minutes.
Memory mode
Your blood pressure monitor can store the readings of 80 (2x40)
measurements. Storing is done automatically after each com-
pleted measurement. The memory is non-volatile. This means
that you will not lose stored data when changing batteries.
Once the memory is full, the oldest values will be overwritten.
How to review the memory
Make sure the product is in power o mode.
Press the memory/average function button. The LCD will
display the past 7 days average of blood pressure rst.
Press the memory/average function button again and the
latest reading will display.
Press it again and the next reading will display.
Average function: 7 day average
Press the memory/average function button once, and the
“7 day average result will show on LCD.
Make sure the date / time is correct when taking a measure-
ment, so you will get the correct 7 day average result.
If there is no data in memory within past 7 days,
will show on LCD.
How to delete the memory data
Make sure the product is in power o mode.
Press the memory/average function button for at least 10
seconds.
LCD will display “del no as shown.
Press the memory/average function button again. LCD will
display “del yes”.
If you are sure all the data of corresponding user can be
deleted, press “power” button, all the corresponding user’s
data will be deleted and the device will shut down.
Note: if you have set delete yes”, but do not press a button
for 2 minutes, the product will shut o automatically, but the
5. If your wrist position is accurate the the green arm icon on
the device will appear with a black outline and the device will
sound “BEEP BEEP BEEP BEEP”. Directly following the the four
beeps the device will automatically inate and begin taking
the user’s reading. When the measurement is complete the
reading is displayed on the LCD.
Top: systolic value
Middle: diastolic value
Bottom: pulse
If the measuring position is incorrect, the measurement can’t
start, so there is no possibility to obtain a wrong or inaccurate
measurement.
The device will beep rapidly if the positioning system is incor-
rect. You have to move your arm up or down according to the
arrow indication on the LCD screen.
If your wrist position is at the correct level with your heart, the
LCD will display and the measurement will start.
Measuring arm: if your wrist position is lower than your
heart, the LCD will display as shown and will beep as
“BEEP BEEP BEEP BEEP”.
If your wrist position is higher than your heart, the LCD will
display as shown and will beep as ” BEEP BEEP BEEP BEEP.
If the positioning system has been deactivated, you will have
no indication before processing the measurement.
Please note:
In case of system errors or handling mistakes, the display
will show an error code, instead of giving you inaccurate
results (for details, please see section «What to do if…»).
BEEP BEEP BEEP BEEP
BEEP BEEP BEEP BEEP
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Braun BPW 4100 VitalScan at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Braun BPW 4100 VitalScan in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 8,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info