4 Commissioning
Ask your contractor to provide information about how the boiler
works and is operated.
Never undertake any modifications or maintenance.
4.1 Preparing the heating system for operation
For the contractor to be able to commission the heating system, observe
the following:
Check that the required operating pressure has been set.
Check the flange connections and other connections for tightness
(water/fuel).
Open the fuel supply to the main fuel shut-off valve.
Switch on the heating system emergency stop switch.
Have your contractor show you how to top up the water
( also Chapter 7.2, page 7).
4.2 Operating the control unit and burner
Start your boiler at the control unit (in this example, Fig. 3:
CFB 930 control). The adjustments made in the control unit will affect
the burner as well. The burner can then be started by the control unit.
For further details, see the operating instructions of the particular
control unit or burner.
Set the boiler temperature controller [2] to 105 °C. Set the ON/OFF
switch [6] to "I" (ON).
Fig. 3 Control unit, example CFB 930 control
[1] High limit safety cut-out
[2] Boiler temperature controller
[3] F1, F2 Fuse
[4] MEC
[5] Burner emergency operation switch
[6] Appliance on/off switch
5 Decommissioning
5.1 Shutting down the heating system
Shut your boiler down via the control unit (e. g. CFB 930 control,
Fig. 3, page 6). This also switches the burner off automatically.
Set the ON/OFF switch ( Fig. 3, [2]) to "0" (OFF).
Isolate the fuel supply to the burner.
5.2 Shutting down the heating system in an emergency
Never put your life at risk. Your own safety is paramount.
In other cases of danger where there is no actual risk to life and limb,
immediately shut off the main fuel shut-off valve and isolate the
heating system via the fuse in the boiler room or via the heating
system emergency stop switch ( Chapter 1.2, page 3).
Isolate the fuel supply to the burner.
Guard against unintentional re-connection.
Open the automatic air vent valve only briefly for venting.
Observe the operating requirements of BG01 for hot
water boilers (UK).
Follow the control unit's operating instructions.
1 2 3 4 5 6
6 720 806 032-47.1ITL
NOTICE: System damage due to frost.
The heating system can freeze up during a power failure
or if the power supply has been switched off!
Check the "Control unit settings" to ensure the
heating system remains operational (especially when
there is a risk of frost).
Switch off the heating system by means of the fuse in the
boiler room or the heating system emergency stop
switch only in emergency situations that pose an
immediate risk to life and limb.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Uni 3000 F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Uni 3000 F in the language / languages: English as an attachment in your email.

The manual is 0,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch Uni 3000 F

Bosch Uni 3000 F Installation Guide - English - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info