10 | General information
Uni 3000 F6 720 812 901 (2014/10)
Ventilation
Never leave windows slightly open for ventilation purposes. Otherwise,
heat will be constantly discharged from the room without significantly
improving the room's air. It is better to fully open windows briefly.
Close thermostatic radiator valves whilst airing rooms.
Domestic Hot Water (DHW)
Always set the hot water temperature to as low as possible.
A lower setting on the thermostat means a higher rate of energy savings.
Furthermore, higher hot water temperatures result in increased
limescale deposits and thereby impair the function of the appliance
(e.g. longer heating-up times or lower output).
Circulation pump
If necessary, set an existing circulation pump for hot water to your
individual requirements using a timer (e. g. mornings, midday, and
evenings).
Circulation and charge pumps can also be used to ensure thermal
disinfection. Ask your contractor for more information on thermal
disinfection of your hot water system.
Now you know how to heat economically with the Bosch appliance.
Contact your installer should you have further questions - alternatively,
write to us.
10 General information
Operating pressure/water quality
Cleaning the boiler jacket
Wipe down the boiler jacket with a damp cloth. Never use aggressive or
corrosive cleaning agents.
Appliance details
When requesting a customer service visit, it is useful to provide detailed
information about your device.
You will find these details on the type plate or the additional type plate
( Installation and service instructions).
Oil/gas floor-standing boiler (e. g. Uni 3000 F):
...................................................................................................
Serial number: ............................................................................
Commissioning date:
...................................................................................................
Correct fuel
This heating system requires the correct fuel to ensure perfect
operation. During commissioning, your heating contractor will enter the
correct fuel type for your heating system in the table below.
Operating pressure/water quality
Minimum operating pressure
(top up if pressure drops below value) ________________ bar
Set operating pressure
(optimum value) ________________ bar
Maximum heating system operating
pressure (excess pressure activates
pressure relief valve) ________________ bar
Top-up water needs to be treated.
Yes/No
Table 3 Operating pressure (entered by heating contractor)
NOTICE: Risk of system damage through use of
incorrect fuel.
Only use the fuel intended for your heating system.
We recommend you seek the advice of your heating
contractor if you intend to change the fuel for your
heating system.
Use only the following fuel:
Stamp/Signature/Date
Table 4
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Uni 3000 F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Uni 3000 F in the language / languages: English as an attachment in your email.

The manual is 0,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch Uni 3000 F

Bosch Uni 3000 F Installation Guide - English - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info