10
3 Specifications
4 Special accessories
BZ45U20 Pipe set: for use of the continuous-flow heater as an under
sink appliance.
Priority switch (load shedding relay) BZ45L21:
for operation with the priority circuit.
Mounting set BZ45K24M: for surface-mount installation.
Truncated connecting piece sealed at rear for water connection from
below (e. g. cold water connection via fitting mounted below heater):
5 Operating instructions
Please read and observe the detailed safety instructions at the start
of these instructions!
Important: The appliance may never be exposed to frost!
WARNING:
Risk of electric shock!
Switch off the mains voltage supply immediately if a fault occurs.
Immediately shut off the cold water supply to the appliance should
it leak.
6 Getting to know your appliance
The continuous-flow heater heats the water as it flows through the
appliance. The appliance only consumes power during this period.
This appliance can supply hot water to taps in several different locations.
It should be installed close to the tap that is used the most frequently.
This will enable you to reduce energy consumption.
7 Operating the appliance
Turn on the hot-water tap.
The continuous-flow heater switches on automatically and heats the
water as it flows through the appliance.
The heater switches off again when you turn off the tap.
7.1 Increasing the water temperature
When the tap is turned on fully, it is possible that the heater capacity is
not sufficient to heat the water to the required temperature.
Turn the tap off slightly. The water flows through the appliance more
slowly and reaches a higher temperature as a result.
7.2 Decreasing the water temperature
Mix with cold water.
7.3 Saving energy
To minimise energy consumption when turning off the hot water:
Turn off the hot-water tap slowly in order to use the residual heat of
the continuous-flow heater.
This also prevents the water temperature from briefly increasing
above the preselected temperature if the hot-water tap is turned on
again within the next few minutes.
To obtain particularly uniform hot-water temperatures, it is
recommended to use thermostatically-controlled premixers.
The thermostatically-controlled premixer must be suitable for
hydraulically controlled continuous-flow heater.
7.4 Winter operation
Note: It is possible in winter that the supply temperature of the water is
reduced and the required outlet temperature is no longer achieved.
TR1000 12 B
Rated power as delivered [kW] / Rated voltage
Connection Options
12 kW  Y  400 V 3 ~ (11 kW  Y  380 V 3 ~)
8.0 kW 230 V ~ (7.4 kW 220 V ~)
6.0 kW 230 V ~ (5.5 kW 220 V ~)
Switch-on point [I/min] 3.6
Mixed water [I/min] at rated power
approx. 38°C 6.5
approx. 50°C
(supply temperature 12°C)
4.4
Maximum flow pressure of appliance [MPa (bar)] 1.0 (10)
Minimum flow pressure of appliance [MPa (bar)]
1)
1) Plus any pressure loss at the tap mixer.
with flow limiter 0.3
without flow limiter 0.2
Maximum inlet water temperature [ °C] 20
Energy efficiency class A
Load profile XS
Annual energy consumption [kWh] 474
Daily energy consumption [kWh] 2,170
Sound power level [dB] 15
Hot water heating energy efficiency [%] 39
Elbow joint, “cold” (right) Order no. 056169
Elbow joint, “hot”, (left) Order no. 255568
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch TR1000 12 B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch TR1000 12 B in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info