458026
14
Zoom out
Zoom in
Previous page
1/68
Next page
TA 211 E
14
English
Timed se back
Operation
Automatic switching between normal and re-
duced operation according to the time switch
program.
Select this position when the thermal in-
sulation in your building is not so good and re-
duced heating operation is necessary (e. g., at
night) to prevent considerable cooling. During
reduced operation, the appliance remains in
operation with reduced temperature for any
outdoor temperature and the pump runs.
7.2.3 Continuous Normal
Operation
The flow temperature is not reduced.
Select this setting when you will be stay-
ing up late as an exception (e. g., party). In this
case, the setting on the time switch (accesso-
ry) for reduced operation is ignored. Do not
forget to switch back again later to automatic
switching operation .
7.3 Setting the Heating Curve
The heating curve determines the flow tem-
perature to which the appliance is limited,
based on the measured outside temperature.
With a correctly set heating curve, a constant
room temperature is maintained for any out-
door temperature.
The heating curve (Fig. ) of the TA 211 E re-
sults from a base point (c) and the maximum
feed temperature (e).
When commissioning, set flow temperature
control so that the dot is pointing to the right
(Fig. , e).
7.3.1 Base Point Adjustment (c)
The base point of the heating curve sets the
flow temperature (radiator temperature) in °C
when the outside temperature is +20 °C. It
can be set to values between 10 and 60 (°C).
The heating curve shown in Fig. is for a
base point of 25 °C. This setting of the base
point should be selected as a first starting
point.
In case your heating equipment permits,
select a lower setting value (e. g. 20). In case
the room temperature is too low with fully
opened thermostat valves, select a higher
value. (e. g. 30).
7.3.2Adjustment of
the Maximum Feed
Temperature (e)
On the flow tempera-
ture selector in the fa-
cia (e), the maximum heating flow tempera-
ture can be set between approx. 40 °C and
approx. 90 °C.
The maximum flow temperature selected here
is only reached with an outside temperature of
–15 °C (Fig. , Point e).
Note: The feed temperature selector (e) is
also the switch for summer operation
(, left end position).
Therefore, note the setting for the
average feed temperature (Fig. ,
Point e) for winter operation.
The required radiator temperature (flow tem-
perature) for an outdoor temperature of
–15 °C is contained in the design data of the
heating system. If this information is not avail-
able, values gained by experience must be
used.
If for very low outdoor temperatures and
completely open thermostat valves, it is too
cold in the rooms, select a setting value that is
a 1/2 scale division higher (Fig. , e). If for
very low outside temperature and fully opened
thermostatic valves, it is too warm in the
rooms, select a setting value that is a 1/2 scale
division lower (Fig. , e).
-40 -10
0
-30 -20
Tip
Tip
4
1
10 40
50
60
20 30
4
Tip
E
2
5
3
4
1
ECO
E
4
4
Tip
4
4
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch TA 211E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch TA 211E in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 0,65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info