697306
37
Zoom out
Zoom in
Previous page
1/192
Next page
Rectifying faults | 37
6 720 815 257 (2014/10)MS 200
5 Rectifying faults
The indicator shows the operating condition of the module.
6 Environment / disposal
Environmental protection is a fundamental corporate strategy of the
Bosch Group.
The quality of our products, their efficiency and environmental safety
are all of equal importance to us and all environmental protection
legislation and regulations are strictly observed.
We use the best possible technology and materials for protecting the
environment taking into account of economic considerations.
Packaging
We participate in the recycling programmes of the countries in which our
products are sold to ensure optimum recycling.
All of our packaging materials are environmentally friendly and can be
recycled.
Old electrical and electronic appliances
Electrical or electronic devices that are no longer
serviceable must be collected separately and sent for
environmentally compatible recycling (in accordance
with the European Waste Electrical and Electronic
Equipment Directive).
To dispose of old electrical or electronic devices, you
should use the return and collection systems put in place
in the country concerned.
Use only original spare parts. Any damage resulting from
spare parts that are not supplied by the manufacturer is
excluded from liability.
If a fault cannot be rectified, please contact the responsible
service engineer.
If the coding card is set to 0 for more than 2 seconds when
the power supply is switched on, all module settings are
reset to their default settings. The user interface issues a
fault display.
Restart the module.
Indicator
light
Possible cause Remedy
Constantly
OFF
Coding switch set to 0. Set the coding card.
Power supply
interrupted.
Switch on the power supply.
Fuse faulty.
When the power supply is switched
off, replace the fuse ( Fig. 17,
page 173)
Short circuit in BUS
connection.
Check BUS connection and repair if
required.
Constantly
red
Internal fault Replace module.
Flashing
red
Coding switch in
invalid position or in
intermediate position.
Set the coding card.
Flashing
green
Maximum cable length
for BUS connection
exceeded.
Make shorter BUS connection
The solar module
detects a fault. The
solar system continues
to run in the
controller's emergency
mode ( fault text in
fault history or service
manual).
The system yield is largely maintained.
Nevertheless, the fault should be
remedied when maintenance work is
next performed on the system at the
latest.
See fault display on
the user interface
display.
The relevant user interface
instructions and the service manual
contain further information on
troubleshooting.
Constantly
green
No fault. Normal mode.
Table 26
0
1
2
3
4
5
6
7
8
9
10
6 720 647 922-52.1O
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch MS 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch MS 200 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 18,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info