If the flat-pleated filter(28) becomes damaged, replace it
immediately.
Loosen the two locking screws(38) and push the
closing(19) flap latch downwards.
Pull on the closing flap(18) and open the filter
cover(39).
Hold the flat-pleated filter(28) by the supports and take
it out from above.
Use a damp cloth to remove any dust and dirt that ac-
crues around the closing edge of the filter cover(39)
when removing the flat-pleated filter(28).
Insert the cleaned (or a new) flat-pleated filter(28), en-
suring that it is positioned correctly and securely.
Close the filter cover(39) (you should hear it click into
place).
Push the closing(19) flap latch up again and tighten both
locking screws(38).
Cleaning the container
Wipe the container (1) from time to time using a non-ab-
rasive off-the-shelf cleaning product and leave it to dry.
Cleaning the fill level sensors (see figure J)
Make sure that the fill level sensors are cleaned (40) occa-
sionally.
Open the catches (13) and remove the top part of the va-
cuum cleaner (12).
Clean the fill level sensors (40) using a soft cloth.
Put the top part of the vacuum cleaner (12) on and close
the catches (13).
Storage and transport (see figureK)
Before transporting the dust extractor, remove any full
disposal bags or safety filter bags and empty any liquids
that have been absorbed, in order to prevent back injur-
ies.
Wrap the power cable around the cable holder(17).
Insert the accessories into the holders provided for them:
Suction tubes(33) into the holders(20), crevice
nozzle(29) into the holder(21), floor nozzle(32) into
the holder(22).
Open the elastic bands of the vacuum hose holder(4)
and wrap the vacuum hose(25) around the top part of
the dust extractor in the holder(4).
Hook the elastic bands back in.
Only ever carry the dust extractor by the carrying
handle(10).
Store the dust extractor in a dry room and secure it so
that it cannot be used by unauthorised persons.
Put the castor brake(15) down to hold the castors(16)
in place.
Rectifying faults
uIf a fault (e.g. a filter damage) occurs, the vacuum
cleaner must be switched off immediately. The fault
must be repaired before resuming operation.
Warning! The dust extractor contains dust particles that pose a risk to health. Observe all the safety warnings in these in-
structions.
Problem Corrective measures
Suction turbine will not switch on. Check the mains cable, mains plug, fuse, socket and fill level sensors (40).
The mode selector switch (7) is set to "automatic start/stop".
Set the mode selector switch (7) to the "vacuuming" symbol or switch on the
power tool plugged into the plug socket (5).
The suction turbine switches off. Empty the container (1).
The suction turbine will not switch on
again after the container has been
emptied.
Switch the dust extractor off and wait five seconds before switching it back on.
Clean the fill level sensors (40) and the space between the fill level sensors (40)
using a brush.
The suction power is decreasing. Remove any blockages from the vacuum nozzle, suction tube (33), vacuum hose
(25) or flat-pleated filter (28).
Change the disposal bag (27) or safety filter bag (26).
Make sure the filter cover (39) is engaged correctly.
Place the top part of the dust extractor (12) on correctly and close the catches
(13).
Change the flat-pleated filter (28).
Dust is escaping during extraction Check that the flat-pleated filter (28) has been fitted correctly.
Change the flat-pleated filter (28).
Bosch Power Tools 1 609 92A 7Z8 | (23.06.2022)
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GAS 35 H AFC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GAS 35 H AFC in the language / languages: All languages as an attachment in your email.

The manual is 8.9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info