Calibration of Horizontal Surfaces for Grade Measurement (seefigureI)
The surface onto which you place the measuring tool must not deviate from
the horizontal surface by more than 5°. If the deviation is greater, the calib-
ration process is discontinued with the indicator ‑‑‑.
Switch on the measuring tool and position it on the horizontal sur-
face so that the spirit level for horizontal alignment(9) faces up-
wards and the display(7) faces you. Wait 10s.
Then press and hold the calibration buttonUnitsCal(20) for ap-
prox. 2s until CAL1 appears briefly on the display. Then the meas-
ured value(n) will flash on the display.
Turn the measuring tool 180° around the vertical axis so that the
spirit level for horizontal alignment(9) still faces upwards but the
display(7) is facing away from you. Wait 10s.
Then press the calibration buttonUnitsCal(20) again. CAL2 will be
shown briefly on the display. Then the measured value(n) (no
longer flashing) will appear on the display. The measuring tool has
now been recalibrated for this supporting surface.
Note: If the measuring tool is not rotated around the axis described in step
, calibration may not be completed.
Calibration of Vertical Surfaces for Grade Measurement (seefigureJ)
The surface onto which you place the measuring tool must not deviate from
the vertical surface by more than 5°. If the deviation is greater, the calibra-
tion process is discontinued with the indicator ‑‑‑.
Switch on the measuring tool and position it on the vertical surface
so that the spirit level for vertical alignment(10) faces upwards and
the display(7) faces you. Wait 10s.
Then press the calibration buttonUnitsCal(20) for approx. 2s un-
til CAL1 appears briefly on the display. Then the measured
value(n) will flash on the display.
Turn the measuring tool 180° around the horizontal axis so that the
spirit level for vertical alignment(10) faces downwards and the
display(7) is facing away from you. Wait 10s.
Then press the calibration buttonUnitsCal(20) again. CAL2 will be
shown briefly on the display. Then the measured value(n) (no
longer flashing) will appear on the display. The measuring tool has
now been recalibrated for this supporting surface.
Note: If the measuring tool is not rotated around the axis described in step
, calibration may not be completed.
Maintenance and Service
Maintenance and Cleaning
Keep the measuring tool clean at all times.
Never immerse the measuring tool in water or other liquids.
Wipe off any dirt using a damp, soft cloth. Do not use any detergents or
solvents.
The areas around the outlet aperture of the laser in particular should be
cleaned on a regular basis. Make sure to check for lint when doing this.
When the measuring tool is exposed to rain for an extended period, its func-
tion may be impaired. However, after completely drying off, the measuring
tool is ready for operation. No calibration is required.
Only store and transport the measuring tool in the protective bag(22).
If the measuring tool needs to be repaired, send it off in the protective
bag(22).
After-Sales Service and Application Service
Our after-sales service responds to your questions concerning maintenance
and repair of your product as well as spare parts. You can find explosion
drawings and information on spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you with any ques-
tions about our products and their accessories.
In all correspondence and spare parts orders, please always include the
10‑digit article number given on the nameplate of the product.
Malaysia
Robert Bosch Sdn. Bhd.(220975-V) PT/SMY
No. 8A, Jalan 13/6
46200 Petaling Jaya
Selangor
Tel.: (03) 79663194
Toll-Free: 1800 880188
Fax: (03) 79583838
E-Mail: kiathoe.chong@my.bosch.com
www.bosch-pt.com.my
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
1 609 92A 7M1 | (28.04.2022) Bosch Power Tools
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GAM 270 MFL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GAM 270 MFL in the language / languages: All languages as an attachment in your email.

The manual is 10.75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info