Inspection and maintenance
37
Condens 7000 WP – 6721841195 (2022/01)
Operate the appliance.
Fig. 46 Replacing the flue gas temperature sensor
10.16.4 Replacing the coding plug
NOTICE
Damage due to electrostatic charge
Printed circuit boards in electronic components are susceptible to
electrostatic charge (ESD).
Wear an earthed wrist strap when working on electronic components
( § 7.1, p. 18).
Switch off the appliance.
Open the top appliance cover ( § 7.2, p. 18).
Detach the bracket of the burner control unit [1].
Push the burner control unit to the left [2].
Lift the front of the burner control unit so the coding plug is easily
accessible [3].
Remove the coding plug [4].
Attach new coding plug.
Fig. 47 Replacing the coding plug
Mount the burner control unit again by following the above steps in
reverse order.
Screw down the bracket of the burner control unit.
Close and secure the top panel.
Operate the appliance.
10.16.5 Replacing the air/gas ratio control valve
Take the replacement interval of the air/gas ratio control valve into
account.
If the air/gas ratio control valve is defective or depending on the
service life, replace it ( table 18, page 36).
Switch off the appliance.
Close gas isolator.
Follow the replacement instructions provided when replacing the air/
gas ratio control valve.
▶Open the gas cock.
Operate the appliance.
Check the tightness of all gas-carrying components.
0010036539-001
1
0010035231-001
1.
3.
4.
2.
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Condens GC7000WP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Condens GC7000WP in the language / languages: English as an attachment in your email.

The manual is 15.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch Condens GC7000WP

Bosch Condens GC7000WP User Manual - English - 12 pages

Bosch Condens GC7000WP Installation Guide - German - 60 pages

Bosch Condens GC7000WP User Manual - German - 12 pages

Bosch Condens GC7000WP Installation Guide - Dutch - 56 pages

Bosch Condens GC7000WP User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info