Operation
29
Condens 7000 WP – 6721841195 (2022/01)
Settings menu
The factory settings are highlighted in the following table.
Meu item Settings/adjustment range Remark/restriction
Hydraulics
Low-loss header Connection of temperature sensor on the low loss header
Off Low loss header not installed in the system
NTC on device Low loss header installed, temperature sensor
connected to wall mounted boiler
NTC on module Low loss header installed, temperature sensor
connected to heating circuit module
NTC off Low loss header installed, but no temperature sensor
connected
DHW configuration Not installed
3-way valve installed
Cyl. prim. pump inst. after low loss hdr.
Cyl. primary pump installed
HC1 configuration Not installed
Dedicated pump inst. after low loss hdr.
Pump config. Heating pump
Heating
Max. heat output 50 100% Maximum released heat output [%].
On natural gas devices:
Measure the gas rate.
Compare the measurement obtained with the setting
tables (Chapter 15.6, page 49).
Correct deviations.
Standby time 5 … 10 … 60 min The time interval specifies the minimum waiting time
between switching on the burner and switching it on
again.
Anticyc. temp. off 2 … 6 15 K The difference between the current flow temperature and
the set flow temperature until the burner is switched off.
Anticycle temp. on -15 -6 ... 2 K The difference between the current flow temperature and
the set flow temperature until the burner is switched on.
Hot water
Max. DHW output 50 100% Maximum approved DHW output [%].
DHW circ. pump Off
•On
Cycle circ. pump 1 x 3 minutes/h
2 x 3 minutes/h
3 x 3 minutes/h
4 x 3 minutes/h
5 x 3 minutes/h
6 x 3 minutes/h
Permanent
The DHW circulation pump goes into operation 1 ... 6
times per hour for 3 minutes, or into continuous
operation.
TD-Temperature 60 70 … 80 °C DHW temperature during thermal disinfection.
Start TD Start now? Start thermal disinfection.
Stop TD Cancel now? Cancel thermal disinfection.
Pump
Pump ctr. mode Energy saving
Heat demand
Save energy: intelligent shutdown of heat pump for
heating systems with weather-compensated
controller. The heating pump is only switched on if
required.
With heat demand: the flow temperature controller
switches the heating pump. If there is heat energy
demand, the heating pump starts up with the burner.
Min. output 10 ... 100 % Pump output at minimum heat output. Only available if
Pump range map is set to 0.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Condens GC7000WP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Condens GC7000WP in the language / languages: English as an attachment in your email.

The manual is 15.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch Condens GC7000WP

Bosch Condens GC7000WP User Manual - English - 12 pages

Bosch Condens GC7000WP Installation Guide - German - 60 pages

Bosch Condens GC7000WP User Manual - German - 12 pages

Bosch Condens GC7000WP Installation Guide - Dutch - 56 pages

Bosch Condens GC7000WP User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info