44 en | Settings AMAX panel
2019.08 | 11 | F.01U.309.277 Installation Manual Bosch Security Systems B.V.
This option is only configurable if IPv4 DHCP is disabled.
IPv4 subnet mask
This option sets the address of the IPv4 sub-network mask. Possible values are 0.0.0.0 to
255.255.255.255.
This option is only configurable if IPv4 DHCP is disabled.
IPv4 default gateway
This option sets the address of the local network gateway to the internet or intranet. Possible
values are 0.0.0.0 to 255.255.255.255.
This option is only configurable if IPv4 DHCP is disabled.
IPv4 DNS server IP
This option sets the IPv4 DNS server IP address in static IP mode. Possible values are 0.0.0.0
to 255.255.255.255.
This option is only configurable if IPv4 DHCP is disabled.
IPv6 DNS server IP
This option sets the IPv6 DNS server IP address in static IP mode. Possible values are
0000:0000:0000:0000:0000:0000:0000:0000 to FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF.
UPnP (universal plug and play) enable
This option enables / disables devices to connect to the network. If this option is enabled, IP
devices discover each other's presence on the network and can connect to communicate. If
this option is enabled, a router can forward port numbers, allowing reports to reach receivers
behind the router.
HTTP port number
This option defines the web server port number. Possible values are 1 to 65535.
If TLS enhanced security is enabled, HTTPS is applied instead of HTTP. The default value for
HTTPS is 443.
ARP cache time (sec)
This option defines the time-out for ARP cache entries (in seconds). Possible values are 1 to
600.
Web/USB access enable
This option enables / disables authorized users to view and modify the B426-M configuration
parameters through a standard web browser or the B450-M configuration through a USB
connection.
Web/USB access password
This option defines the password required to log in for web access. Possible values are ASCII
printable characters. The length must be 4 to 10 characters.
Firmware upgrade
This option enables / disables the module’s firmware to be modified via the external web
interface. If this option is disabled, the module’s firmware has to be modified through the
control panel.
Module hostname
This option allows the user to customize a hostname for the module. Once set, this hostname
can be used to contact the control panel via RPS over network. If enabled, a web browser can
connect to this communication unit at this hostname for the purposes of configuration and
diagnostics.
If this field is left blank, the module will determine its hostname based on its MAC address
(the factory default hostname).
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AMAX panel 4000 EN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AMAX panel 4000 EN in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch AMAX panel 4000 EN

Bosch AMAX panel 4000 EN Quick start guide - German - 76 pages

Bosch AMAX panel 4000 EN Quick start guide - Dutch - 76 pages

Bosch AMAX panel 4000 EN Installation Guide - Dutch - 190 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info