697454
43
Zoom out
Zoom in
Previous page
1/170
Next page
AMAX panel Settings | en 43
Bosch Security Systems B.V. Installation Manual 2019.08 | 11 | F.01U.309.277
6.1.3 Test report duration
There are two types of automatic test reports, configurable periodic reports and regular daily
reports. The periodic test is sent according to the configuration (interval, hour and minute)
and the local time. Therefore, the date and time of the system has to be set correctly. When
the time that is configured as hour and minute is reached, a periodic test report is sent. The
next periodic test report is sent after the configured interval and is not influenced by any
other reports sent in between periodic test reports.
Test report interval
The test report interval can be set to 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 8 hours, 12
hours or 24 hours.
The periodic test report can be disabled. Regular daily automatic test reports will be sent
instead.
Test report hour
In this option the reference hour from which the test report interval will be started can be
entered. Values from 00 - 23 are valid. An invalid value will be treated as 00.
Test report minute
In this option the reference minute from which the test report interval will be started can be
entered. Values from 00 - 59 are valid. An invalid value will be treated as 00.
6.1.4 Dual IP
Dual IP Settings are valid only when used with Conettix IP communication format. For IP
module 1 and 2, B426-M module are used. IP module 2 does not support RPC connection.
When the report is transmitted with Conettix IP communication, some reports might be
missed.
The communication path of B426-M module / B450-M module is as follows:
Module Address Setting Corresponding
Communication Path
Module 1: B426-M module 1 /
B450-M
134 Paths 1 and 2
Module 2: B426-M module 2 250 Paths 3 and 4
Only when IP module 1 is used and set to paths 1 to 4, the report can be sent to those paths.
6.1.5 IP communicator
Modules
The modules B426-M and B450-M can be connected to the AMAX panel and used as IP
communicators.
B426-M can be set as module 1 or 2. B450-M can only be set as module 1.
For more information on B426-M and B450-M, refer to the corresponding manuals.
IPv6 mode
This option enables / disables the IPv6 mode. If this option is disabled, the IPv4 mode is used.
IPv4 DHCP
This option enables / disables the IPv4 DHCP. If a DHCP service is available is this option is
enabled, the IPv4 address, the IPv4 subnet mask, the IPv4 default gateway, the IPv4 DNS
server IP and alternative IPv4 DNS server IP are configured automatically.
IPv4 address
This option sets the IPv4 address. Possible values are 0.0.0.0 to 255.255.255.255.
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AMAX panel 4000 EN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AMAX panel 4000 EN in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch AMAX panel 4000 EN

Bosch AMAX panel 4000 EN Quick start guide - German - 76 pages

Bosch AMAX panel 4000 EN Quick start guide - Dutch - 76 pages

Bosch AMAX panel 4000 EN Installation Guide - Dutch - 190 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info