The charging procedure starts as soon as the
mains plug is plugged into the socket and the bat-
tery is inserted into the charging compartment 5.
To charge Bosch batteries without contact
APTs 1, an additional adapter 3 must be
used.
To remove the adapter 3 from the charging com-
partment 5, press the unlocking button 2.
Due to the intelligent charging method, the charg-
ing condition of the battery is automatically de-
tected and the battery is charged depending on
battery temperature and voltage.
This gives longer life to the battery and always
leaves it fully charged when kept in the charger
for storage.
Control of the charging procedure is indicated via
the charge control LED 4:
Rapid-charging procedure
The rapid-charging procedure is in-
dicated by flashing of the charge
control LED 4.
The battery is fully charged as soon as the LED 4
switches from flashing to being lit continuously.
Afterwards the battery can be removed for imme-
diate use.
The rapid-charging procedure is possible
only when the temperature of the battery is
between 0 °C and 45 °C.
Trickle-charging procedure
The trickle-charging procedure is
indicated by continuous lighting
of the LED 4.
With the battery fully charged, the charger imme-
diately switches to trickle-charge mode. This
equalizes the natural running-down of the battery
again.
No charging procedure possible due to
defective battery
If a malfunction of the charging
procedure is present, this will be in-
dicated through continuous light-
ing of the charge control LED 4.
The charging procedure can not be started and
the battery can not be charged.
Possible cause of trouble:
The battery temperature is not within the allow-
able temperature range.
Corrective measure: Get the battery tem-
perature within the allowable temperature
range (0 °C to 45 °C) either by cooling down or
warming up. As soon as the battery tempera-
ture is within the allowable temperature range
again, the battery charger automatically
switches to rapid charging.
The contacts of the battery are contaminated.
Corrective measure: Clean the contacts
(e. g. by inserting and removing the battery
several times) or replace the battery, as re-
quired.
The battery is defective, due to a disconnec-
tion in the battery (individual cells).
Corrective measure: Replace the battery.
The charge control LED 4 does not
light up
The charge control LED 4 does not light up after
inserting the mains plug into the socket.
Possible cause of trouble:
The charger plug is not inserted (properly).
Corrective measure: Insert the plug (fully)
into the socket.
Socket, cable or charger are defective.
Corrective measure: Check the mains volt-
age and if necessary, have the charger
checked from an authorized customer service
station for Bosch power tools.
With continuous or several repetitive charging
cycles without interruption, the charger can
warm up. This in not meaningful and does not
indicate a technical defect of the unit.
A battery that is new or has not been used for
a longer period does not develop its full capac-
ity until after approximately 5 charging/dis-
charging cycles.
A significantly reduced working period after
charging indicates that the batteries are used
and must be replaced.
Charging Procedure
Fault Finding and
Trouble-Shooting
Practical Advice
8 • 2 609 931 772 • 03.03
8


Need help? Post your question in this forum.

Forumrules
1

Forum

bosch-al-60-dv-1419

Reset search

  • GREEN LIGHT REMAINS ON,BUT DOES NOT SHOW OUTPUT VOLTAGE
    Submitted on 4-8-2020 at 07:58

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AL 60 DV 1419 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AL 60 DV 1419 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info