16 | Commissioning
AGS10-2, AGS10E-2, AGS20-2, AGS50-26 720 811 270 (2015/04)
6.3.2 Checking the flow rate
Refer to Tab. 13 for the required flow rate (at 30-40 °C in the return).
Check the flow rate in the sight glass of the flow limiter (
Fig.
27
[3]).
6.3.3 Setting the flow rate
It may be necessary to reduce the flow rate for solar systems with up to
4 flat plate collectors (or 3 evacuated tube collectors).
Set the speed to 100 % on the solar controller ( controller
instructions: "Function test").
If the maximum flow rate ( Tab. 14) is exceeded:
Reduce the flow rate at the flow limiter [2] until the flow rate drops
below the maximum.
After commissioning
The viscosity of the heat transfer fluid makes air bubbles substantially
more resilient than those in pure water.
After several hours of solar pump operation, vent the solar system via
the air separator in the solar pump station [4] and (if installed) the air
vent on the roof.
Fig. 27
[1] Gravity brake ready for operation
[2] Adjusting screw on the flow limiter, depending on the type
[3] Read-off edge for the flow rate, depending on the type
[4] Ventilation at the air separator
If the pre-set flow rate is not reached at the pump's
highest speed stage:
Check maximum permitted pipe lengths and sizing
( Chapter 4.1).
If necessary, install a more powerful solar pump.
Quantity Flat plate l/min
1)
1) Nominal flow rate per collector: 50 l/h
Evacuated tube l/min
2)
2) Nominal flow rate per collector: 30 l/h
1 1 0.5-0.6
2 1.5-2 1-1.2
3 2.5-3 1.4-1.8
4 3-4 1.9-2.4
5 4-5 2.4-3.0
6 5-6 2.9-3.6
7 5.5-7 3.3-4.2
8 6.5-8 3.8-4.8
9 7.5-9 4.3-5.4
10 8-10 4.8-6.0
11 9-11 5.2-6.6
12 10-12 5.7-7.2
13 10.5-13 6.2-7.8
14 11.5-14 6.7-8.4
15 12.5-15 7.1-9.0
16 13-16 7.6-9.6
17 14-17 8.1-10.2
18 15-18 8.6-10.8
19 15.5-19 9.0-11.4
20 16.5-20 9.5-12.0
Table 13 Maximum flow rate at 30 - 40 °C in the return depending on
collector version and number of collectors
Low energy pumps do not require a step switch as they
are modulated using a control signal.
Quantity Flat plate l/min Evacuated tube l/min
1 2.5 --
2 5 5
3 7.5 7.5
4 10 10
Table 14 Flow rate (maximum flow rate) at 30 - 40 °C in the return
depending on collector version and number of collectors
0,5
7
6
5
4
3
2
1
L/min
7
6
5
4
1
0,5
3
2
6720801165.19-2.ST
1
20
0
40
60
°C
80
100
120
20
0
40
60
°C
80
100
120
S E
3
2
4
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch AGS50-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch AGS50-2 in the language / languages: English as an attachment in your email.

The manual is 2,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info