GB
Thank you for buying a BORETTI product which has been manufactured to the highest quality standards to meet your require-
ments.
We recommend you carefully read this booklet in which you will find instructions for installation, hints for use and mainte
-
nance.
1 ELECTRICAL
This cooker hood is fitted with a 3-core mains cable with a standard 10/16A earthed plug.
Alternatively the hood can be connected to the mains supply via a double-pole switch having 3mm minimum contact gap
on each pole.
Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside
the cooker hood.
Technical Specification: Voltage 220-240, single phase ~50Hz / 220 V - 60 Hz.
2 INSTALLATION ADVICE
Ensure the cooker hood is fitted in compliance with the recommended fixing heights.
To ensure the safe operation of this cooker hood, we recommend that the hood should not be fitted below 65cm (for electric)
or (70cm for gas) the measurements taken from the surface of the cooking appliance to the underside of the cooker hood.
It is a possible fire risk if the hood is not sited as recommended.
To ensure the best results, the cooking fumes should be able to rise naturally towards the inlet grilles on the underside of
the cooker hood and the cooker hood should be positioned away from doors and windows, which will create turbulence.
Ducting
If the room where the hood is to be used contains a fuel-burning appliance such as a central heating boiler then its flue
must be of the room sealed or balanced flue type.
If other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to the room. Ensure the
kitchen is fitted with an airbrick, which should have a cross-sectional measurement equivalent to the diameter of the ducting
being fitted, if not larger.
The ducting system for this cooker hood must not be connected to any existing ventilation system, which is being used for
any other purposes or to a mechanically controlled ventilation ducting.
The ducting used must be made from fire retardant materials and the correct diameter must be used, as incorrect sized
ducting will affect the performance of this cooker hood.
When the cooker hood is used in conjunction with other appliances supplied with energy other than electricity, the negative
pressure in the room must not exceed 0.04 mbar to prevent the fumes from combustion being drawn back into the room.
The appliance is for domestic use only and should not be operated by children or people who are infirm without supervi
-
sion.
This appliance must be positioned so that the wall socket is accessible.
3 FITTING
Any permanent electrical installation must comply with the latest regulations concerning this type of installation and a qualified
electrician must carry out the work. Non-compliance could cause serious accidents or injury and would deem the manufacturers
guarantee null and void.
IMPORTANT - The wires in this mains lead are coloured in accordance with the following code :
green / yellow : earth blue : neutral brown : live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows.
- The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter
E or by the earth symbol or coloured green or green and yellow.
- The wire which is coloured blue must be connected to the terminal which is marked with the letter
N or coloured black.
- The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
1) Draw a vertical line up the wall from the centre of the cooking appliance below as illustrated in fig. 4 - item 1.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Boretti PRO 100 IX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Boretti PRO 100 IX in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 5,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info