20
Installation
www.bora.com
5 4
3
2
1
Fig. 5.20 Cooking zone connection in 180° installation
[1] Cooktop
[2] Rear cooking zone (zone 2)
[3] Front cooking zone (zone 1)
[4] Rear cooking zone control knob (zone 2)
[5] Front cooking zone control knob (zone 1)
Connect the connection on the back of the left control
knob [5] to the “zone 1” connection on the back of the
cooktop [1].
Connect the connection on the back of the right
control knob [4] to the “zone 2” connection on the
back of the cooktop [1].
Using the configuration menu, set the correct
allocation of the cooking zones in the control
knob display (see Configuration menu, 0° or 180°
installation).
Connecting the automatic extraction system
Connect the cooktop extractor to the cooktop using the
connector provided for the automatic extraction system.
5.5.6 Establishing the power connection
Observe all safety and warning information (see the
Safety chapter).
Observe all national and regional laws and regulations
as well as the supplementary regulations of the local
utility companies.
INFO The power connection may only be established by
certified specialists. The specialist also assumes
responsibility for the proper installation and
commissioning.
INFO This appliance is intended to be operated on
a supply network with an impedance Zmax at
the transfer point (mains connection) of 0.104
ohms maximum. The user is to ensure that the
appliance is only operated on a mains supply
network which meets this requirement. If
necessary, ask the local energy supply company
about the system impedance.
The power supply line to be used (pre-assembled) must
be at least Type SiHF.
(see table Fuse protection and minimum cross-section.
Connection Fuse protection Minimum
cross-section
1-phase connection 1 x 25 A
2.5 mm
²
2-phase connection 2 x 16 A
2.5 mm
²
Tab. 5.4 Fuse protection and minimum cross-section
If the connection cable has been damaged this must
be replaced. This may only be done by an authorised
member of the After Sales Service team.
Switch off the main switch/automatic circuit breaker
before connecting the cooktop.
Secure the main switch/automatic circuit breaker
against being switched back on without permission.
Make sure the power to the appliance is disconnected.
Only connect the cooktop using a permanent
connection to a power supply cable.
1
L1 L2
2
N PE
220 - 240 V~
220 - 240 V~
3
Fig. 5.21 Connection diagram 2-phase
1
L1
2 3
N PE
220 - 240 V~
Fig. 5.22 Connection diagram 1-phase
Check that installation has been carried out correctly.
Switch on the main switch/automatic circuit breaker.
Put the cooktop into operation (see the Operation
chapter).
Check that all the functions are working correctly.
Connecting the cooking zones when the cooktop is
installed rotated by 180°
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bora Pro PKT11 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bora Pro PKT11 in the language / languages: English as an attachment in your email.

The manual is 3,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bora Pro PKT11

Bora Pro PKT11 User Manual - German - 36 pages

Bora Pro PKT11 User Manual - Dutch - 36 pages

Bora Pro PKT11 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info