714520
20
Zoom out
Zoom in
Previous page
1/44
Next page
EN
20
Assembly
www.bora.com
Flush installation
x
764 ±2
735 ±2
519 ±2
R5
R5
50
50
490 ±2
600
Fig. 6.3 Dimensions of cut-out for ush installation
6,5 +0,5
14,5
10 - 50
Fig. 6.4 Dimensions of groove for ush installation
Surface installation
x
735 ±2
≤ R5
50 50
490 ±2
≥ 600
Fig. 6.5 Dimensions of cut-out for surface installation
12,5
10 – 50
Fig. 6.6 Dimension of support for surface installation
A false floor underneath the cooktop with integrated
cooktop extractor is not needed.
The drawers and/or shelves in the floor unit must be
removable.
A return flow aperture > 500 cm
2
is required in the
kitchen units for recirculation appliances (e.g. by
shortening the plinth boards or using suitable slatted
plinths).
The power socket is underneath the device on the front.
6.3.3 Cooktop air intake
The components in the cooktop which generate heat are
automatically cooled. The warm air is extracted by fans
(cold air flow).
INFO In order to retain the full functionality of the
cooktop in the long term, there must be suffi-
cient ventilation underneath the cooktop.
INFO The performance of the cooktop is impaired or
the cooktop overheats if the warm air below
the cooktop cannot escape.
INFO If the cooktop overheats, performance is re-
duced or the cooktop switches off completely
(see Overheating protection).
INFO For sufficient air intake, an opening cross-sec-
tion in the kitchen units of at least 50 cm
2
is
recommended.
Ensure there is sufficient ventilation underneath the
cooktop.
INFO If there are plans for a cable protection floor
(false floor) below the device, this must not
impede the ventilation.
6.4 Dimensions of cut-out for
cooktop
Worktop overhang
50x
Fig. 6.2 Worktop overhang
Please note the worktop overhang x when creating
the worktop cut-out. Applies to flush installation and
surface mounting.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bora BIAS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bora BIAS in the language / languages: English as an attachment in your email.

The manual is 7,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bora BIAS

Bora BIAS User Manual - German - 44 pages

Bora BIAS User Manual - Dutch - 44 pages

Bora BIAS User Manual - French - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info