497119
12
Zoom out
Zoom in
Previous page
1/18
Next page
12
en
30
31
Remove the plastic cup and the pink styrofoam piece
from the cartridge (38) and retain for future use (the
refill resin consists of 3 refill bags) (39).
Close the cartridge (40).
Soak the demineralization cartridge in a water bath
24 hours before using it (43). The resin has to absorb
water to reach high performance. If it is soaked in the
tank, make sure to exchange the water and empty the
water from the base before using the humidifier.
Screw the cartridge on the water tank cap (44).
Screw the cartridge on the bottom side of the water
tank, put the tank on the main body (45).
Placing granules in the center of the cartridge
allows them to escape in the unit or to clog the
unit. The unit will no longer operate properly and
the granules need to be cleaned out thoroughly.
Option B: replace the whole cartridge
Remove the water tank from the base and unscrew the
water tank cap (30). Caution: the mist outlet is loose!
The demineralization cartridge is attached to the tank
cap. Unscrew the cartridge from the cap by turning it
counter-clockwise (31). Important: do NOT dispose of
the water tank cap!
Throw the whole cartridge into the waste (41).
Unpack the new cartridge (42).
Soak the demineralization cartridge in a water bath
24 hours before using it (43). The resin has to absorb
water to reach high performance. If it is soaked in
the tank, make sure to exchange the water and empty
the water from the base before using the humidifier.
Screw the cartridge on the water tank cap (44). Close
tank cap well and place the tank on the main body
(45).
Replacement of the demineralization
cartridge
Always unplug the unit before removing the
water tank. Do not touch the water in the base
during operation!
The water tank is equipped with a demineralization cart-
ridge. This cartridge has to be replaced every 2 – 3 months.
If the water is very hard, it may be necessary to replace the
cartridge earlier. White dust around the device is a sure sign
that the cartridge needs replacing. Please note white dust
is not harmful. If white residue still forms around the device
after a new cartridge has been inserted, please make sure
that the water you are using is untreated. If the water flows
through a decalcification systemsuch as an ion exchanger
– (sodium is added to remove calcium) in the building before
it is used in the humidifier, salt can precipitate as white dust
around the device. The demineralization cartridge and or the
granules must be exchanged at the latest after 6 months or
the unit does not reach its full performance anymore.
Option A: replace the resin
Remove the water tank from the base and unscrew the
water tank cap (30). Caution: the mist outlet is loose!
The demineralization cartridge is attached to the tank
cap. Unscrew the cartridge from the cap by turning it
counter-clockwise (31). Important: do NOT dispose of
the water tank cap!
Open the cartridge (32).
Throw the content into the waste (Attention! Disposed
resin can make the floor slippery!) (33).
Place the enclosed pink styrofoam piece in the center
of the cartridge. Do not push it to the bottom as it will
be difficult to remove afterwards (34).
Pour the contents of one refill resin bag into the plastic
cup that is included with the refill resin packaging (35).
Place the empty cartridge with the plug in the center
onto the plastic cup (36).
Turn the plastic cup and cartridge over and shake until
all resin is in the cartridge (37).
32 33
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Boneco AOS 7142 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Boneco AOS 7142 in the language / languages: English as an attachment in your email.

The manual is 1,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info