814356
20
Zoom out
Zoom in
Previous page
1/24
Next page
20
Power level
1, 2
lowest level,
warmest internal temperature
3
medium level,
recommended operating temperature
4, 5*
highest level,
coldest internal temperature
*Beware of high setting because the maximum level may
already mean "freezing point".
Basically, the temperature changes depending on the
ambient temperature (place of installation), the fre-
quency of opening the door and the equipment.
For initial operation, first set the lowest possible inter-
nal temperature (= highest power level) until the ap-
pliance has reached the desired operating tempera-
ture. It is recommended to reset to a medium power
level afterwards, then you can easily make any tem-
perature correction. A high power level also in-
creases energy consumption.
The recommended cooling temperature for optimized
storage is approx. 12 degrees.
Interior light
The indoor light is switched on or off via the on/off
switch at the appliance back.
Equipment
Note that the equipment varies depending on the ap-
pliance type.
The various shelves or drawers can be height-ad-
justed (partially and model-dependent) or removed
for individual storage. Practical also for cleaning pur-
poses.
NOTE:
For the most efficient use of energy, place all
shelves/drawers in their original positions.
Removing / inserting the shelves
To remove, open the unit door completely, lift the
shelf, if necessary, slant slightly and pull it out to
the front.
Safely reinsert the shelf at the desired height and
push it in until the stop is reached.
Storing
Several storage levels for inserting the grid shelf, al-
lows individual storage.
Loading examples:
- 44 cans à 330 ml (70 x 120 mm)
- 32 bottles à 500 ml (70 x 170 mm)
Store large bottles horizontally, with the opening fac-
ing forward on the grid shelf.
Operating noise
Type of sound
Cause
Mumbling
Compressor during its operation
Liquid sounds
Circulation of the refrigerant
Click sounds
The temperature control turns
the compressor on or off
Disturbing
noises
Vibration of the shelves or cool-
ing coils
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bomann KSG 7286 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bomann KSG 7286 in the language / languages: English, German as an attachment in your email.

The manual is 0.66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info