57
Prior to Initial Start–Up
Please clean the appliance interior and all accessories prior to initial start-up (see section: “Cleaning and
Care”).
Plug socket
The plug socket necessary for connection of your appliance to the electricity supply should be positio-
ned so that it is possible to pull out the appliance plug.
If your appliance is installed under a continuous worktop, the
plug socket should be provided as shown.
A concealed protective contact plug socket requires 10 A/16 A
fusing.
If the socket is not accessible once the appliance is built in, the
electrical installation must include suitable means of isolating
the appliance from the mains (e.g. fuse, cut-out, current trip or
similar with a minimum contact separation of 3 mm).
☞
Before initial start-up, refer to the appliance serial plate to ascertain if supply voltage and current values
correspond with those of the mains at the installation location.
e.g.: AC 220 ... 240 V 50 Hz or
220 ... 240 V ~50 Hz
(i.e. 220 to 240 volts alternating current, 50 Hertz)
The rating plate is inside the appliance on the left.
☞
Description of the appliance
View of the appliance
➀
Butter/cheese
compartments with
flap
➁
Door storage
compartment
➂
Bottle shelf
➃
Vegetable drawers
➄
Storage shelves
➅
Temperature regulator
and light switch
➆
Freezer compartment
➇
Rating plate