ENGLISH
from the mains power supply. This is done by
placing insulation barriers between the
electrical and mechanical components making
it unnecessary for the tool to be earthed.
Note: Double insulation does not take the place
of normal safety precautions when operating the
tool. The insulation system is for added protection
against injury resulting from a possible electrical
insulation failure within the tool.
ELECTRICAL SAFETY
Be sure the supply is the same as the voltage given on
the rating plate. The tool is fitted with a two-core cable
and plug.
MAINS PLUG REPLACEMENT (UK ONLY)
Should the mains plug need replacing and you are
competent to do this, proceed as instructed below.
If you are in doubt, contact a Black & Decker service
centre or a qualified electrician.
Disconnect the plug from the power supply.
Cut off the plug and dispose of safely. A plug with
bared copper conductors is very dangerous if
engaged in a live socket outlet.
Only fit BS1363A approved plugs fitted with the
correctly rated fuse.
Note: Fuses do not give personal protection against
electric shock.
The cable wire colours, or a letter, will be marked at
the connection point of most good quality plugs.
Attach the wires to their respective points in the plug
(see diagram). Brown is L (live) and blue is N (neutral).
Fit a 5 amp fuse
approved
to BS1362
N
L
E
230 volts AC only
Never use a light
socket
Make sure that the
outer sheath of the
cable is held firmly
by the clamp
Fit a BS1363A
approved
resilient plug
Connect
blue to
N (neutral)
Connect
brown to
L (live)
Before replacing the top cover of the plug ensure
that the cable restraint is holding the outer sheath of
the cable firmly and that the two leads are correctly
fixed at the terminal screws. If the fuse cover is
missing or damaged do not use the plug. For
replacement or detachable fuse covers, contact a
Black & Decker service centre.
Warning! Never connect live or neutral wires to the
earth pin marked E or .
MAINS PLUG REPLACEMENT
(AUSTRALIA AND NEW ZEALAND ONLY)
Should the mains plug or cordset of the product be
damaged, it must only be replaced by an authorised
Black & Decker service agent because special
purpose tools are required.
EXTENSION CABLES
Up to 30m (100ft) of Black & Decker 2-core extension
cable (or 3-core extension cordset, in Australia and
New Zealand) can be used without undue loss of power.
Note: An extension cable should not be used unless
absolutely necessary. Use of an improper extension
cable could result in a risk of fire and electric shock.
If an extension cable must be used, make sure it is
properly wired, contains the correct rated fuse as
recommended in its literature and is in good
electrical condition.
UNWANTED TOOLS AND THE ENVIRONMENT
Should you find one day that the tool needs
replacement or is of no further use, think of the
protection of the environment. Black & Decker
service centres will accept old tools and will
dispose of them in an environmentally safe way.
THE BLACK & DECKER GUARANTEE
(UK, AUSTRALIA AND NEW ZEALAND ONLY)
If the Black & Decker product becomes defective due
to faulty materials and workmanship, within 24 months
from the date of purchase, we guarantee to either
replace all defective parts or at our discretion, replace
the unit free of charge provided that:
The product is returned to us or our authorised
repairers with evidence of date of purchase.
The product has not been used for trade,
professional or hire purposes.
The product has not been subjected to misuse
or neglect.
The product has not sustained any damage through
foreign objects, substances or accidents.
Repairs have not been attempted by anyone other
than our own service staff or authorised repair
distributors.
KR580-700 ML p21-35 05-02-2001, 10:4822
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Black Decker KR580CRE T4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Black Decker KR580CRE T4 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 8,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info