ENGLISH
To ensure continued safe operation,
check the chain tension as described
in this manual after every 10 minutes
of use, and adjust back to a clearance
of 3 mm as required.
Double insulation
Your chainsaw is double insulated.
This means that all external metal parts are
electrically isolated from the power supply.
This is achieved by placing an extra insulation
barrier between the electrical and mechanical
parts. Double insulation means greater
electrical safety and obviates the necessity
of having the machine earthed.
Electrical safety
Make sure your chainsaw is correct for your
supply. The voltage can be found on the rating
plate.
Fuse replacement (UK & Ireland only)
If you need to replace the fuse on your extension
cable, please note the following:
The plug should be fitted with a 13 amp fuse
which is the recommended fuse for your chainsaw.
Only use replacement fuses which are
approved to BS1362.
When changing the fuse in your plug, always
ensure the fuse cover is refitted.
If the fuse cover is missing or damaged do not
use the plug. Note: Fuses do not give personal
protection against electric shock.
Plug replacement (UK & Ireland only)
We strongly recommend the use of PVC or rubber
covered plugs or connectors with your chainsaw.
Disconnect the plug from the supply.
Cut off the plug and dispose of it immediately.
Insertion of a detached plug into a 13 amp
socket outlet may result in electric shock.
Only fit BS1363A approved plugs fitted with
the correctly rated fuse (1).
The cable wire colours, or a letter, will be
marked at the connection points of most good
quality plugs. Attach the wires to their
respective points in the plug. Brown is for
“Live” (L) (2) and blue is for “Neutral” (N) (4).
Before replacing the top cover of the mains
plug ensure that the cable restraint (3) is
holding the outer sheath on the cable firmly
and that the two leads are correctly fixed at the
terminal screws.
Warning! Never connect live or neutral
wires to the earth pin marked “E” or .
Note: Do not wire an extension cable
directly into your chainsaw.
Increased safety can be obtained by having a
qualified electrician install a high sensitivity
(30 mA / 30mS) circuit breaker in the house wiring.
If you do not wish to have one installed, then we
strongly recommend that the electrical power to
your chainsaw be supplied through a high
sensitivity residual current device (RCD). The RCD
is designed to provide a high degree of personal
protection against harmful electric current should
fault conditions occur.
Warning! The use of an RCD or other
circuit breaker unit does not release the
operator of your chainsaw from the safety
instructions and safe working practices
given in this user manual.
We recommend that if your mains cable is cut or
requires replacement that you return your chainsaw
to a Black & Decker service agent. When repaired,
your chainsaw will be tested for electrical safety.
Cable connection system (UK only)
Black & Decker continually makes every effort to
achieve the highest standards in performance,
quality and reliability. We recommend the use of a
new outdoor cable connection system, which
gives additional protection against the possibility
of water or moisture entering into the cable
connector during normal use.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Black Decker GK1640 T4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Black Decker GK1640 T4 in the language / languages: English as an attachment in your email.

The manual is 1,06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Black Decker GK1640 T4

Black Decker GK1640 T4 User Manual - English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Spanish, Norwegian, Finnish - 128 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info