644566
8
Zoom out
Zoom in
Previous page
1/83
Next page
8
- Important: Danger of poisoning, do not
inhale emissions.
- Never operate the generator in non-
ventilated rooms. When operating the
generator in rooms with good ventilation, the
exhaust gases must be channeled directly
outdoors through an exhaust hose.
- Place the generator at least 1m away from
buildings and the equipment connected to it.
- Wear suitable ear protection when in the
vicinity of the equipment.
- The values quoted in the technical data for
sound power level (LWA) and sound pressure
level (LWM) are emission values and not
necessarily reliable workplace values. As
there is a correlation between emission
and emission levels, the values are not a
reliable basis for deciding on any additional
precautions which may be needed. Factors
inuencing the actual user emission level
include the properties of the work area, other
sound sources etc., the number of machines
and other processes in the vicinity, as well
as the time span in which the operator is
subjected to the noise. Also, the permitted
emission level can vary from country to
country. Nevertheless, with this information
the user is able to make a better assessment
of the dangers and risks involved.
CAUTION: Read all safety regulations and
instructions.
Any errors made in following the safety
regulations and instructions may result in an
electric shock, re and/or serious injury.
Keep all safety regulations and instructions
in a safe place for future use.
3. Proper Use
The generator is intended to provide
electric tools and light sources with
electricity. When using the device with
household appliances, please check their
suitability in accordance with the relevant
manufacturer’s instructions. In case of doubt,
ask an authorized dealer of the respective
appliance. The machine is to be used only
for its prescribed purpose. Any other use is
deemed to be a case of misuse. The user /
operator and not the manufacturer will be
liable for any damage or injuries of any kind
caused as a result of this.
The device is designed for applications
operated with a 230V alternating current
source for 230V.
4. Technical Data
Generator
Generator type: Synchronous
Ingress Protection: IP23M
Rated voltage Urated: 230 Va.c. / 12V d.c.
Continuous rated power Prated (S1): 2,0 kW
Maximum power Pmax(S2) :
2,2 kW (S2, 2min)
Frequency Frated: 50 Hz
Power factor: Cos
φ
=1
Performance class: G1
Operating mode S1 (continuous operation)
The machine can be continuously operated
with the quoted power output.
Operating mode S2 (temporary operation)
The machine may be temporarily operated
with the quoted power output. Afterwards
the machine must be stopped for a while to
prevent it from overheating
Engine
Engine model: PD168F
Engine design:
Single-cylinder forced air-cooled 4-stroke
OHV
Spark plug: LG F6TC
Displacement: 196 cm
3
Tank capacity: 18 L
Engine oil: Appox.0,6 l (15W40/<0 °C: 5W30)
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Black Decker BD 2200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Black Decker BD 2200 in the language / languages: English, German, Dutch, Italian, Spanish, Finnish as an attachment in your email.

The manual is 1,97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info