Ensure that the daylight therapy lamp is positioned on a stable base.
Please ensure that the TL 55 is only operated in the following positions (vertical and horizontal) and that it
is placed safely on a flat surface. The device must not be operated when laid down or covered!
The device must only be connected to the mains voltage that is specified on the type plate.
Never submerge the device in water or other liquids and do not use it in the bathroom.
It must not be used on people with disabilities, children under 3 years of age or people with reduced sen
-
sitivity to heat (e.g. people with skin alternations due to illness), after taking pain relief medication, alcohol
or drugs.
Keep packaging material away from children (risk of suffocation!).
The device should not be covered, uncovered, or packed and stored when warm.
Always unplug the mains part and allow the device to cool down before touching it.
Do not touch the device with wet hands when it is plugged in and do not allow water to spray on the de
-
vice. Only operate the device if it is completely dry.
Ensure that you only insert and remove the mains part with dry hands and that you only press the ON/
OFF button with dry hands.
Keep the mains cable away from hot objects and open flames.
Protect the device from heavy impact.
Do not pull the mains part out of the socket using the mains cable.
Do not use the device if it shows signs of damage or does not function properly. In such cases, contact
Customer Services.
If the mains connection cable of this device is damaged, it must be disposed of. If it cannot be removed,
the device must be disposed of.
Disconnection from the power supply network is only guaranteed when the mains part is unplugged.
Do not use the device in the presence of flammable anaesthetic gas connections with air, oxygen or nitro
-
gen oxide.
No calibration and no preventive checks or maintenance are to be carried out on this device.
You cannot repair the device. The device contains no parts that you can repair.
Do not make any changes to the device without the manufacturer's permission.
If the device has been changed, thorough tests and checks must be carried out to ensure the continued
safety of further use of the device.
As the patient/user, you can operate all functions of this device.
General notes
Important
Always consult a doctor before using the device if you are taking medication such as pain relief medica-
tion, medication to reduce high blood pressure or antidepressant medication.
Diabetics and people who suffer from retinal diseases must be examined by an optician before using the
device.
Please do not use the device if you suffer from an eye disease such as cataracts, glaucoma, diseases of
the optic nerve or inflammation of the vitreous body.
If you have health concerns of any kind, consult your GP!
Remove all packaging material before using the device.
Light sources are excluded from the guarantee.
If you have further questions about using our devices, please contact Customer Service.
Repairs
Important
Do not open the device. Do not attempt to repair the device yourself. This can result in serious injury.
Failure to comply will result in voiding of the warranty.
For repairs, please contact Customer Services or an authorised retailer.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer TL 55 - Day and Night at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer TL 55 - Day and Night in the language / languages: English, German, Danish, French, Italian, Polish, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 6,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info