14
•
Add 5 drops of the “LW110 Fresh” water additive for each litre of filled water. The water additive changes
the water hardness. The evaporation improves as the water is prevented from rolling off the plastic surface
and the humidification discs remain moistened with water.
•
Place the upper cover with integrated fan unit on the tub. If the upper cover cannot be placed precisely
onto the tub, turn the upper cover around 180 degrees. This is a design feature and ensures that the fill
level sensor contacts touch each other.
IMPORTANT
•
Do not add any essential oils or fragrances. If other additives are used, the plastic material may
become discoloured and damaged.
•
Ensure the water level in the tub with inserted humidification discs never goes above the lower edge
of the “MAX” marking on the inside of the tub.
Positioning the device
•
Position the air washer in the vicinity of a heated object to improve evaporation, in particular in large rooms
(do not exceed a max. temperature of 50 °C). Always ensure that the air inlet and air outlet remain clear
and that the air flows freely.
•
Insert the mains plug into the socket. Ensure that the cable does not pose a trip hazard. You can clamp
the mains cable in the vertical ridge and lead it downwards.
6. Operation
Switch on the device using the On/off button in the centre of the upper cover. The display lights up, shows
fan level 0 and the water fill level.
Select the fan speed using the fan button in the centre of the upper side.
Graphic displayed Fan level
Level 0, standby – fan off
Level 1, low
Level 2, medium
Level 3, maximum
The water level gauge indicates the tub fill level:
Graphic displayed Fill level
Approx. 4.3 l to 7.25 l
Approx. 2.5 l to 4.3 l
Approx. 0.5 l to 2.5 l
Residual water in the tub.
The tub must be refilled.
The device has switched itself off due to safety reasons. Clean and refill the device
to carry out the initial use process again.