3. Closing the atomiser
Close the lid of the medicine container (2) and click
the clip in place, and then refit the cover (1).
4. Fitting accessories
When the required accessories (mouthpiece, adu
lt mask or child mask) have been attached to the
device, attach the device firmly to the assembled
medicine container (2).
The adult mask and child mask must be fitted us-
ing the connecting piece (12) (adapter).
Now place the device to your mouth and close your
lips firmly around the mouthpiece. When using ei-
ther of the masks, place it over the nose and mouth.
Start the device using the on/off button (5).
The spray mist coming from the device and the il-
luminated blue LEDs (4) show that the device is
working perfectly.
5. Inhaling correctly
Breathing technique
The right breathing technique is important to en-
sure that the particles are distributed as widely as
possible into the air ways. So that they can enter
the air ways and lungs, you must inhale slowly and
deeply, hold your breath briefly (5 to 10 seconds)
and then exhale quickly.
You should only use nebulisers to treat respiratory
disorders if advised to do so by your doctor, who
will recommend the medicine, dose and applica-
tion for inhalation therapy.
Certain medicines are only available on prescription.
Note
You should hold the device as upright as possi-
ble. Tilting it slightly will not, however, affect its
function, since the container is leakproof. To en-
sure that the device functions correctly, make sure
that you do not tilt it more than 45 ° in any direction
and that the medicine is in contact with the mesh
while in use.
Important
Essential oils, cough medicines, solutions designed
for gargling, and drops for application to the skin or for
use in steam baths are wholly unsuitable for inhalation
using a nebuliser. These substances are often highly
viscous and can impair the correct function of the de-
vice and hence affect the effectiveness of its applica-
tion in the long term.
In the case of oversensitivity of the bronchial system,
medicines containing essential oils can sometimes
cause acute bronchiospasm (a sudden, cramp-like
tightening of the bronchi accompanied by breathless-
ness). Always ask your doctor or pharmacist for advice!
6. End of inhalation
After treatment, switch off the device using the on/
off button (5).
The LEDs (4) go out.
Once the inhalant has been fully sprayed out, the
device switches off automatically.
For technical reasons, a small amount may still re-
main in the medicine container (2).
Do not use it.
If applicable, disconnect the power pack (13) from
the mains.
7. Clean the device
For information about this, see “Cleaning and disinfec-
tion” on page 16.
8. Cleaning and disinfection
Warning
Observe the following hygiene instructions in order to
avoid any health risks.
The nebuliser and accessories are intended for
multiple use. Please note that cleaning and hygien-
ic reconditioning requirements differ according to
the different areas of application.
Note
Do not clean the mesh or accessories with brushes
or similar, as this may cause irreparable damage,
and this will mean that the intended result of the
treatment is no longer guaranteed.
For additional requirements regarding the neces-
sary hygienic preparations (hand washing, han-
dling of medicines or inhalation solutions) in high-
risk groups (e.g. cystic fibrosis patients), contact
your doctor.
Cleaning
The mesh atomiser and container, as well as acces-
sories such as mouthpiece, mask, connecting piece,
etc. must be cleaned with hot water after each use.
Carefully dry all components using a soft cloth. Once
all components are fully dry, reassemble the atomiser
and place the components in a dry, sealed container
or carry out disinfection.
Remove the mouthpiece and any accessories from
the atomiser.
Add 6 ml of clean water to the medicine container
(2) and switch on the device to first remove any
medicine residue from the mesh. (Please spray the
entire liquid).
Remove the batteries.
Remove the detachable parts from the device, e.g.
mesh atomiser or medicine container and cover.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer JIH50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer JIH50 in the language / languages: English, German, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 2,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beurer JIH50

Beurer JIH50 User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info