Connecting an accessory
Now connect the
hose to the acces-
sory connector [1]
on the nebulisa-
tion chamber (im-
age 5).
Now connect the
accessory you
wish to use (mask
with connector or
mouthpiece) to the
hose.
Switch on the device by pressing the ON/OFF but-
ton. When the device is functioning correctly, a mist
is then generated for inhalation.
Airflow control dial
You can adjust the airflow using the airflow control [7].
You can increase the airflow by turning the airflow con-
trol to the left and decrease it by turning it to the right.
Stopping inhalation
When you have finished the treatment, switch off
the device using the ON/OFF button [5].
The LED indicator for the operating display [6]
goes out.
If the inhalant is nebulised, the device switches
off automatically. For technical reasons, a small
amount of medication remains in the medication
container [3].
Do not use this.
Disconnect the mains part [16] from the power
supply.
Carry out cleaning
See 9. “Cleaning and disinfection”.
8. Inhaling correctly
Important
Do not tilt the device or position it at an angle.
Essential oils, cough syrups, gargling solutions and
drops to be used as a rub or in a steam bath are
wholly unsuitable for inhalation using a nebuliser.
Such additives are often viscous and can impair
the correct functioning of the device and the effec-
tiveness of the application in the long-term.
For individuals with a hypersensitive bronchial sys-
tem, medications containing essential oils may un-
der certain conditions cause an acute bronchos-
pasm (a sudden cramp-like restriction of the bron-
chi with shortness of breath). Consult your doctor
or pharmacist in relation to this matter!
Breathing technique
It is important to use the correct breathing tech-
nique to ensure that the particles are distribut-
ed as widely as possible across the airways. To
ensure that the particles reach your airways and
lungs, you must breathe in slowly and deeply, then
hold your breath briefly (5 to 10 seconds) and then
breathe out quickly.
Nebulisers should only be used for the treatment
of respiratory diseases after consultation with your
doctor. He or she will advise you about the selec-
tion, dosage and use of medications suitable for
inhalation therapy.
Certain medications are only available with a pre-
scription.
When inhaling through the mouthpiece
Use the mouthpiece if you are suffering from a
condition of the lower airways, such as a cough or
a bronchial infection.
Sit up straight.
Connect the hose [15] to the accessory connector
[1]. Then connect the mouthpiece [14] to the hose.
Place your lips around the mouthpiece.
Switch on the device by pressing the ON/OFF but-
ton.
Breathe in slowly and deeply through your mouth
and breathe out through your nose. After breathing
in, hold your breath briefly to increase the effec-
tiveness of the therapy. Remain calm and relaxed
during the treatment. Take breaths at regular in-
tervals and do not breathe too fast. If you want to
pause the inhalation for a short time, switch off the
device by pressing the ON/OFF button and take
out the mouthpiece.
When inhaling using the mask
The inhalation mask is suitable for the treatment of
the nasopharynx.
Sit up straight.
Connect the hose [15] to the accessory connec-
tor [1]. Now connect the connector [11] to the hose
and the mask to the connector.
Hold the mask pressed gently against your nose;
the mask must cover your mouth and nose without
squashing them.
5
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer IH 40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer IH 40 in the language / languages: English, German, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 5,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beurer IH 40

Beurer IH 40 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info