568897
16
Zoom out
Zoom in
Previous page
1/80
Next page
16
7. Operation
Preparing the atomiser
Before using them, always clean and disinfect the
water tank, the cover, the connector for the masks,
the extension hose, the mouthpiece and the
masks, according to the instructions under section
9. “Cleaning and disinfection”.
If the therapy involves inhaling several different medi-
cations one after the other, please be aware that the
atomiser must be rinsed under warm tap water fol-
lowing every usage. See section 9. “Cleaning and
disinfection”.
Place the device on an even surface.
Remove the cover (image 1).
Note
Ensure that there is a mains socket close to the
set-up area.
Arrange the mains cable so that no-one will trip
over it.
To disconnect the nebuliser from the mains after
nebulisation, first switch off the device and then
pull the mains plug out of the socket.
Operating the mains part
Only connect the mains part [16] using the voltage
specified on the type plate.
Insert the mains part connector plug [16] into the
provided connector socket [10] and fully insert the
mains part [16] into a suitable mains socket.
Filling the nebulisation chamber
The tank capacity is 20ml. Fill the water tank [4] with
clean water (preferably distilled water) up to the wa-
ter fill line [9]. This water is used as the fluid through
which the ultrasonic waves are guided to the medi-
cation. Do not pour medication directly into the wa-
ter tank.
Filling the medication container
Place the medica-
tion container in the
water tank (image 2)
and then fill it with
the medication (im-
age 3).
Ensure that the
maximum capac-
ity of 8ml is not ex-
ceeded.
Adhere to the
instructions for use
and dosage instruc-
tions for the medi-
cation to be used.
If it is necessary to
dilute a medication
with an isotonic so-
dium chloride solu-
tion, first pour the
solution into the
medication contain-
er and then add the
required dosage of medication.
Closing the nebulisation chamber
Close the nebulisa-
tion chamber using
the cover provided
[2] (image 4).
1
~ 8 ml
2
3
4
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer IH 40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer IH 40 in the language / languages: English, German, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 5,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beurer IH 40

Beurer IH 40 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info