working time and pause time for this program to between 1 and 30
seconds each.
1. Place the electrodes on the desired area for treatment (for
positioning suggestions see electrode positions in section 6.4)
and connect them to the device.
2. Select the EMS 34 program as described in section “5.2 Starting
application” (step 3 to step 5).
3. Use the ˄/˅ setting buttons to select the working time ("on
time") you want and use the ENTER button to confirm.
4. Use the ˄/˅ setting buttons to select the pause time ("off time")
you want and use the ENTER button to confirm.
5. Use the ˄/˅ setting buttons to select the impulse frequency you
want and use the ENTER button to confirm.
6. Use the ˄/˅ setting buttons to select the impulse width you want
and use the ENTER button to confirm.
7.Use the ˄/˅ setting buttons to select the treatment time you want
and use the ENTER button to confirm.
8.Use the left and right ˄/˅ setting buttons for and
to
select the impulse intensity you want.
EMS 35 program
EMS 35 is a burst program that you can also customise. Various
impulse sequences run in this program. Burst programs are suitable
for all areas of application to be treated with changing signal
patterns (to minimise the level of accustoming to the treatment).
In this program, you can set the impulse frequency to between 1
and 150 Hz and the impulse width to between 80 and 450 s. You
can also set the working time and pause time for this program to
between 1 and 30 seconds each.
1. Place the electrodes on the desired area for treatment (for
positioning suggestions see electrode positions in section 6.4)
and connect them to the device.
2. Select the EMS 35 program as described in section “5.2 Starting
application” (step 3 to step 5).
3. Use the ˄/˅ setting buttons to select the working time ("on
time") you want and use the ENTER button to confirm.
4. Use the ˄/˅ setting buttons to select the pause time ("off time")
you want and use the ENTER button to confirm.
5. Use the ˄/˅ setting buttons to select the impulse frequency you
want and use the ENTER button to confirm.
6. Use the ˄/˅ setting buttons to select the impulse width you want
and use the ENTER button to confirm.
7.Use the ˄/˅ setting buttons to select the treatment time you want
and use the ENTER button to confirm.
8.Use the left and right ˄/˅ setting buttons for and
to
select the impulse intensity you want.
8. Doctor’s function
The Doctor’s function is a special setting to allow you to access
your personal program even more easily and directly.
Your individual program settings are instantly recalled and activated
when the device is switched on.
You may wish to adjust this individual program following advice from
your doctor.
Setting the Doctor’s function
Select your program and the corresponding settings as described
in section “5.2 Starting application”.
At the start of the stimulation treatment, the impulse intensity of
and is set to 00 by default. No impulses are sent to the
electrodes yet. Before setting the desired impulse intensity using
the intensity setting buttons, press and hold the ˅-button for
5 seconds. Storage in the Doctors function is confirmed with a
long acoustic signal.
If you switch on the device again, the program you saved using
the Doctor’s function is automatically opened directly.
Deleting the Doctor’s function
To clear the device again and to re-allow access to other programs,
press and hold the ˅-button again for approx. 5 seconds. To
do this, the impulse intensity of and must be set to 00.
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer EM 49 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer EM 49 in the language / languages: English, German, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 17,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beurer EM 49

Beurer EM 49 User Manual - Swedish - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info