You can access stored measured values on the device at any time. Proceed as follows:
1. With the device switched off, press the memory button
M
. The last stored measured value in the
selected user memory is displayed. To access the measured values in the second user memory,
press and hold the memory button
M
for 5 seconds.
2. To navigate between the individual measured values, press the memory button
M
. If you want to
delete the entire memory of the respective user, press the memory button
M
again and press and
hold it together with START/STOP button for 5 seconds.
8. Usage (ECG)
8.1 Preparing the ECG measurement
Observe the following before beginning the ECG measurement:
If the ECG-electrode surfaces are dirty, clean them with a cotton bud soaked in rubbing alcohol.
If your skin or hands are dry, moisten them using a damp cloth before the measurement.
Please note that there must be no skin contact between your right and left hand. Otherwise, the
measurement cannot be taken correctly.
Do not speak or move while carrying out the ECG measurement as this can cause inaccuracies
during the measurement.
When taking the measurement, please keep the device lying flat (horizontally) on the table.
8.2 Measuring ECG
The accuracy of the measurement as well as the ability to perform a measurement with this device
depends on the heart configuration (shape of the heart) of each individual user. If it is not possible
to take stable measurements using this device, this could have a harmless cause such as the
shape of the heart. However, the cause may also be an illness or disease.
Please note that there must be no skin contact between your right and left hand. Otherwise, the
measurement cannot be taken correctly. Stay still during the measurement, do not speak and
hold the device still. Movements of any kind will falsify the measurements.
Maintain constant pressure during the measurement. Do not press the electrodes too firmly
against the skin as this can cause the muscles to tense and give rise to inaccurate measured
values.
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer BM 93 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer BM 93 in the language / languages: English, German, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 12,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info