The device requires approx. 5 seconds to store the deter-
mined measured value.
You can interrupt measurement at any time by pressing the
ON/OFF button
.
To switch off and release the pressure, press the ON/OFF
button
again. If you forget to switch off the device, it
switches off automatically after approx. 1 minute.
Wait at least 5 minutes before taking another measurement!
Evaluating results
Cardiac arrhythmia:
This instrument can identify possible cardiac arrhythmia
disorders during measurement and if necessary indicates the
measurement with the flashing icon
disorders during measurement and if necessary indicates the
.
This may be an indicator for arrhythmia. Arrhythmia is a
condition where the heart rhythm is abnormal as a result of
defects in the bioelectrical system controlling the heart beat.
The symptoms (omitted or premature heart beats, slow or ex-
cessively fast heart rate) may be caused, among other things,
by heart disease, age, physical predisposition, excessive use
of stimulants, stress or lack of sleep. Arrhythmia can only be
ascertained through examination by your doctor.
Repeat the measurement if the flashing icon
ascertained through examination by your doctor.
is displayed
after the measurement. Please note that you should rest for 5
minutes between measurements and not talk or move during
the measurement. If the icon
minutes between measurements and not talk or move during
appears often, please
contact your doctor. Any self-diagnosis and treatment based
on the test results may be dangerous. It is vital to follow your
doctor‘s instructions.
WHO classification:
The World Health Organization (WHO) and National High
Blood Pressure Education Program Coordinating Commit-
tee have developed a blood pressure standard, according
to which areas of low- and high-risk blood pressure are
identifi ed. This standard, however, is a general guideline as
individual's blood pressure varies among different people
and different age groups...etc.
It is important that you consult with your physician regularly.
Your physician will tell you your normal blood pressure range
as well as the point at which you will be considered at risk.
Table for classification of blood pressure values (unit of measurement mmHg) for adults:
Range Systolic Diastolic Action
Hypotonia
(degraded blood pressure) lower than 105 lower than 60 Check with doctor
Normal range between 105 and 120 between 60 and 80 Self check
Pre-hypertensive
blood pressure range*
between 120 and 140 between 80 and 90 Check with doctor
High blood pressure - degree
between 140 and 160 between 90 and 100 Consult your doctor
High blood pressure - degree
higher than 160 higher than 100 Consult your doctor
(*) Blood pressure range that might transfer to high blood pressure Adapted from JNC 2003
15


Need help? Post your question in this forum.

Forumrules
1

Forum

beurer-bm-16

Reset search

  • THE BLOOD MONITOR DOES NOT TURNINIG ON,BEFORE IT WORK CORRECTLY WITH THE SPECIAL ADAPTER Submitted on 29-1-2022 at 19:09

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beurer BM 16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beurer BM 16 in the language / languages: English, German, French, Italian, Polish, Turkish, Spanish as an attachment in your email.

The manual is 4,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beurer BM 16

Beurer BM 16 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info