474163
45
Zoom out
Zoom in
Previous page
1/67
Next page
ENGLISH
constant light
Note: If a STOP or emergency-OFF circuit is not
connected to terminals 20 and 71, check
whether the DIP switch 2 (SCH1) is set at
"ON" and DIP switch 1 (SCH2) is set at
OFF.
Lighting: flashes 1 x in 1 second
LED: 3 glows
Cause: A border protection (8,2k)connected to
terminals 20 and 74 has been interrupted or
activated (see section 4.11).
Remedy: Remove the obstruction and/or check the
border protection, if necessary.
Note: If no safety border is connected to terminals
20 and 74, check whether the DIP switch 3 is
set at “OFF” and whether resistor 8,2k is
connected to terminals 20 and 74.
Lighting: flashes 1 x in 1 second
LED: 3 flashes
Cause: A border protection (optical) connected to
terminals 20, 74 and 77 has been interrupted
or activated (see section 4.12).
Remedy: Remove the obstruction and/or check the
border protection, if necessary.
Note: If no safety border is connected to terminals
20, 74 and 77 check whether the DIP switch 3
is set at “OFF” and whether resistor 8,2k is
connected to terminals 20 and 74.
Lighting: flashes 2 x in 3 second
Cause: Due to an overcurrent cutoff, the operator has
reversed twice to the "OPEN" end-of-travel
position.
Remedy: Remove the obstruction. Check the door
action and, if necessary, run through the
learning procedure (see section 3.2.2).
Acknow-
ledgement: Generate another impulse via an external
button, the radio receiver or the PCB button.
Note: This error is only displayed if the automatic
timer is set.
Lighting: flashes 3 x in 4 seconds
Cause: Operator has not yet undergone the learning
procedure (this is simply being brought to your
attention, it does not constitute an error).
Remedy: Run through the learning procedure (section
3.2.2).
Lighting: flashes 4 x in 5 seconds
Cause: see section 6.4
Remedy: see section 6.4
Lighting: flashes 5 x in 6 seconds
Cause: Programming of the automatic timer has been
started (this is simply being brought to your
attention, it does not constitute an error).
Remedy: Run through the learning procedure (see
section 5.6.1).
6.4 Measures following error message
Causes of possible error messages:
- The learned distance is too short, < 60 cm.
- During an automatic travel cycle when running
through the learning procedure, the operating or
"learn" button was pressed.
- During an automatic travel cycle when running
through the learning procedure, the wicket door
contact / photocell input was activated.
- The learning procedure has been started, but no
button has been pressed within 60 seconds.
- The Hall sensor is defective.
6.5
Malfunction and remedy
If your garage door opener is malfunctioning, test the
system according to the following checklist:
ATTENTION
Before carrying out any work on the
operator with the cover removed, it is
essential to unplug it from the mains!
6.5.1 Operator fails to start up
Check whether mains voltage is being supplied.
6.5.2 Operator fails to work with hand transmitter:
If the LED control light does not light up when the
transmitter button is pressed, the battery voltage is too
low. Replace the battery in the hand transmitter. If despite
replacing the battery, the system still fails to work, check
the hand transmitter or receiver.
4 impulses = error
briefly press white button
3 impulses = no valid values in
the memory
carriage must have
engaged
carriage must have
engaged
briefly press white button
press INI button (black) for
6 seconds
door travels slowly to
“CLOSE” position.
Reference cycle without
reversing upon obstacle
2 impulses = learn
impulses
see 3.3.2
operator ready for
operation
operator ready for
operation
45
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Berner GA401 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Berner GA401 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 5,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info