Operation
6005033_0 – 08.11.2019
To achieve an optimal efficiency in removing cooking fumes:
Turn the device on 1-2 minutes before you start cooking.
This allows the flow of air to build up, and the fumes are
removed at an early stage.
In order to collect the cooking fumes effectively, use the
rear hob plates for intensive cooking.
Avoid cross-currents (e.g. draughts) across the hob.
During the cooking process, switch to a power level that
is appropriate for the intensity of the cooking vapours:
yPower level 1 - lowest fan power
yPower level 2 - medium fan power
yPower level 3 - high fan power
If the intensity of the cooking vapours does not subside,
switch to a higher power level.
Switch to the POWER setting if frying.
Turn on the run-on function when you have finished
cooking.
D“4.3.1 Run-on function (page 24).
Check the fresh air supply at regular intervals.
Use the device also to reduce other unpleasant smells.
Such as from:
yOnions and garlic
yOven, microwave and steamer
yFondue and raclette
DWARNING
Fire hazard due to grease residue!
In operation grease residue, which is highly inflammable,
collects in and on the device.
Clean the device properly.
D“5. Cleaning” (page 26).
If you switch the machine on and hear an unusually loud fan
noise:
Clean the device.
Observe the stipulations for cleaning.
D“5. Cleaning” (page 26).
If you switch the machine on and notice a smell:
Change the filter filling.
Observe the stipulations for changing the filter filling.
D“6.2.2 Replacing filter filing (with recirculating and
hybrid mode)” (page 28).
After 6 hours without operation, the device (including
lighting) automatically switches off.
4.3.1 Run-on function
The device comes with a run-on function. If this function is
used, the device will work for a further ten minutes at the last
chosen power level.
In recirculated air mode, it is necessary to use the run-on
function so that the device can remove the remaining
odours. Using the run-on function increases the life of the
filter filling. The filter filling must be replaced at regular
intervals.
The run-on function can be switched on manually or
automatically. The automatic run-on function is activated in
configuration mode.
D“4.4 Configuration (page 25).
Touch
field
Function
The device is switched on.
If the automatic run-on function is activated:
Touch the touch field 1x.
The device switches off.
The run-on time starts automatically in the last
selected power level.
If the automatic run-on function is not
activated:
Touch the touch field 2x - within
2 seconds.
The device switches off.
The run-on time is started manually in the last
selected power level.
During the run-on time (10 minutes), the
operating symbol for the selected power level
will flash.
4.3.2 Extraction mode / recirculated air mode
changeover
If the device is configured for hybrid mode, it is possible to
switch between extraction mode and recirculated air mode
at any time after activating the changeover function.
The changeover function is activated in configuration mode.
D“4.4 Configuration (page 25).
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Berbel BTH 100 ML at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Berbel BTH 100 ML in the language / languages: English as an attachment in your email.

The manual is 13.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Berbel BTH 100 ML

Berbel BTH 100 ML User Manual - German - 36 pages

Berbel BTH 100 ML User Manual - Dutch - 36 pages

Berbel BTH 100 ML User Manual - French - 36 pages

Berbel BTH 100 ML User Manual - Italian - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info