Installation
6005033_0 – 08.11.2019
The connection is made through cable terminals on a
detachable plug on the fan box.
DATTENTION!
Risk of damage through incorrect connection!
A mix-up of the control wires can result in damage to the
electronics.
Be careful not to mix up connections when connecting
the control wires: Core 1 on terminal 1, core 2 on
terminal 2.
2. 1.
Wall box
Connect the wall box as follows:
yCore 1 on terminal 1
yCore 2 on terminal 2
yThe wall box is closed when the control contacts are
open.
yThe wall box is open when the control contacts are
closed.
Window contact switch
Connect the window contact switch as follows:
yBlue/white core to terminal 3
yBrown/green core to terminal 4
yThe hood‘s fan is only operational when the window is
open.
Under-pressure monitor
yThe hood‘s fan is only operational when no critical under-
pressure is determined in the room.
3.5.9 Connect exhaust air ducting (with exhausted
air or hybrid operation)
Extracted air mode
1.
2.
Fit the exhaust outlet onto the guide on the fan housing.
Seal the transition between the exhaust outlet and the
guide with the help of sealing tape.
Ensure that the exhaust air duct is correctly fitted.
Hybrid mode
1.
2.
Fit the exhaust outlet onto the collar of the hybrid filter.
Ensure that the exhaust air duct is correctly fitted.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Berbel BTH 100 ML at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Berbel BTH 100 ML in the language / languages: English as an attachment in your email.

The manual is 13.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Berbel BTH 100 ML

Berbel BTH 100 ML User Manual - German - 36 pages

Berbel BTH 100 ML User Manual - Dutch - 36 pages

Berbel BTH 100 ML User Manual - French - 36 pages

Berbel BTH 100 ML User Manual - Italian - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info