Operation
6006113_a – 01.06.2022
4.4.4 Locking function
In order to prevent undesired changes to the settings of the
cooking zones, the control panel can be locked permanently.
Make sure that all cooking zones are
switched off.
Touch the symbol for 3 seconds.
yThe “Lock” display lights up.
yThe control panel is locked; only the On/Off
button and the symbol remain active.
To switch off the function:
Once again, touch the symbol for
3 seconds.
4.4.5 Extraction operating mode
If the device is connected to a manufacturer‘s extractor
hood, the operating mode for extraction can be set for the
interaction of the devices.
There are three operating modes available for extraction:
yAutomatic mode
yManual mode
ySemi-automatic mode
Touch the symbol to change operating
mode.
The selected operating mode is shown in the 7-segment
display for the extraction. In delivery condition, automatic
mode is activated.
Automatic mode
The setting of the fan power takes
place automatically. The fan is adjusted
automatically to a suitable power level
depending on the cooking zone level that is
selected.
Irrespective of the power, the 7-segment
extraction display always shows A”.
If multiple cooking zones are used, the power
level is adjusted accordingly. The cooking
zone with the highest active power level
determines the fan power.
The power level of the fan can also be
changed manually during operation.
The device remains in automatic mode.
After changing the current highest power
level of a cooking zone, the fan power will be
adapted again automatically.
Manual mode
The setting of the fan power takes place
manually. The connection between the
selection of the cooking zone level and fan
power selection is severed.
Semi-automatic mode
When the cooking zone is switched on
and activated, the fan is also switched on
automatically at power level 2. In further
operation, the connection between the
selection of the cooking zone level and fan
power is severed.
The fan switches off when the cooking zone is
switched off or the automatic run-on starts.
Automatic mode includes pot recognition.
yWhen the cookware is removed from a cooking zone:
The extraction power level is adjusted to the active
cooking zone with the highest power level.
yWhen the cookware is removed from all cooking zones,
or if no cooking zone is active (all power levels = 0):
The automatic run-on function for the extraction is
started. When cooking continues, the run-on function
stops.
A description of the further functions of the menu levels is
provided in the following sections.
yFunctions for the individual cooking zones.
D“4.5 Operation of the cooking zones” (page 19).
yFunctions for extraction.
D“4.7 Operation of the extractor hood (page 23).
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Berbel BKF 90 iPP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Berbel BKF 90 iPP in the language / languages: English as an attachment in your email.

The manual is 7.35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Berbel BKF 90 iPP

Berbel BKF 90 iPP User Manual - German - 36 pages

Berbel BKF 90 iPP User Manual - Dutch - 36 pages

Berbel BKF 90 iPP User Manual - French - 36 pages

Berbel BKF 90 iPP User Manual - Italian - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info