Installation
6006382_a – 17.05.2022
3.5.9 Establish electrical power supply
DWARNING!
Risk of death due to electric shock!
Touching live parts can cause an electric shock, burns or
death.
Make sure that the following work is only carried out by
qualified electricians.
Ensure that the voltage supply is and remains
disconnected while the following work is in progress.
DATTENTION!
Danger of property damage due to incorrect connection!
If the hob is connected with further devices (e.g. oven),
damage can arise due to overvoltage. The customer must
provide a separate connection point with dedicated fuse for
the hob.
Make sure that the device is connected separately.
Make sure the connection is separately protected with a
circuit breaker and a residual current device.
Observe the voltage specifications on the ratings plate.
Connect the hob to the on-site power supply. The junction
box is located on the underside of the device.
Connection to spring-loaded terminals (e.g. in cooker
connection boxes) is not permitted.
3-phase connection of the hob:
L1 black Phase for left cooking zones
L2 grey Phase for right cooking zones
L3 brown Phase for fan
N blue Neutral conductor
PE green/yellow Earth
Cable H 05 VV - F, H 05 RR - F,
Diameter 5 x 2.5 mm2
Fuse 16 A
For a 2-phase connection (fuse 20 A), L2 and L3 must be
bridged.
For a 1-phase connection (fuse 40 A), L1, L2 and L3 must be
bridged.
Route the cables so that they are not kinked, crushed or
damaged and do not come into contact with hot parts of
the device.
Ensure that the cable is not disturbed during replacement
of the filter filling.
Make sure that the device can be disconnected on all
poles from the electricity supply after installation.
Recirculating air kit DL BUR
Insert the cold appliance plug into the connection socket
on the recirculated air filter.
Plug the mains plug into the socket.
After switching on the power supply, the device is ready for
operation.
3.5.10 Check and carry out commissioning
DATTENTION!
Risk of disruptions due to moisture in the device!
If the device is moved from a cold environment into a hot
one, condensation may form inside.
Wait about 2-3 hours before bringing the device into
service.
Ensure that the device is accessible for maintenance work
at all times (e. g. with a removable rear panel or service
cover). The space must be sufficiently large to allow for
removal of the recirculated air filter.
Check that an all-pole isolating device (min. 3 mm contact
gap) is present.
Check that the mains cable and the electrical connection
cable are not kinked, crushed or damaged.
Ensure that the device is not operated without
recirculated air filter or without exhaust elements.
Ensure that the adapters of the air-carrying components
(e.g. conduit bend, shallow duct sections) are sealed with
sealing strip.
Ensure that air outlets are not closed or covered.
With recirculated air devices: Make sure that the
ventilation slots are free.
Make sure that the protective film is removed.
Check the correct functioning of the device.
D“4. Operation (page 23).
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Berbel BKA 90 DLI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Berbel BKA 90 DLI in the language / languages: English as an attachment in your email.

The manual is 15.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Berbel BKA 90 DLI

Berbel BKA 90 DLI User Manual - German - 44 pages

Berbel BKA 90 DLI User Manual - Dutch - 44 pages

Berbel BKA 90 DLI User Manual - French - 44 pages

Berbel BKA 90 DLI User Manual - Italian - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info