Operation
6005145_a – 01.06.2022
4.2.1 Normal operation
DWARNING!
Fire hazard due to grease residue!
In operation grease residue, which is highly inflammable,
collects in and on the device.
Clean the device properly.
D“5. Cleaning” (page 27).
To achieve optimal efficiency in removing cooking fumes:
Turn the device on 1-2 minutes before you start cooking.
This allows the flow of air to build up, and the fumes are
removed at an early stage.
During the cooking process, switch to a power level that
is appropriate for the intensity of the cooking vapours:
yPower level 1 - lowest fan power - when simmering
food.
yPower level 2 - medium fan power - when cooking on
one cooking zone.
yPower level 3 - high fan power - when cooking on
several cooking zones.
If the intensity of the cooking fumes does not subside,
switch to a higher power level.
Switch to the Power setting when searing. After 6 minutes,
the device automatically switches back to power level 3.
To activate the Power setting permanently,
the corresponding button must be pushed again.
Then the device doesn’t switch back.
Check the fresh air supply at regular intervals.
Use the device also to reduce other unpleasant smells.
Such as from:
yOnions and garlic
yOven, microwave and steamer
yFondue and raclette
Turn on the run-on function when you have finished
cooking.
After use, turn the device off. If the automatic run-on
function is activated, the run-on time (10 minutes) starts
in power level 1.
With use of the BackFlow technology, if a power level is
active then a gentle air flow is routed from the air channel
on the underside of the device to the front air inlet. This air
circulation is necessary. The air channel on the underside of
the device must never be closed off.
After 12 hours without operation, the device (including
lighting), the device automatically shuts off.
4.2.2 Extraction mode / recirculated air mode
changeover
If the device is configured for hybrid mode, it is possible to
switch between extraction mode and recirculated air mode
at any time after activating the changeover function.
The changeover function is activated in configuration mode.
D“4.3 Configuring the device” (page 26).
Button Function
If the changeover function is activated:
Touch the button one time.
Button glows dimly:
yThe device operates in extraction mode.
yThe wall box is opened.
yThe cleaned air is discharged outdoors.
Button glows brightly:
yThe device is operating in recirculated air
mode.
yThe wall box is closed.
yThe cleaned air is discharged into the
room.
4.2.3 Filter filling indicator
The device has a control indicator to remind the operator
to change the filter filling. If no air circulation filter is used,
the control indicator has no meaning.
The function is set so that the button flashes every 1,000 fan
operating hours (flash duration 120 seconds) as soon as
the device is turned off. The hours counter is restarted by
switching off the control indicator.
Button Function
Button flashes:
The filter filling must be replaced.
D“6.2.2 Replace filter filling (with
recirculating or hybrid operation)”
(page 29).
Hold the button (> 1 second) to restart the
hours counter.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Berbel BEH 90 GL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Berbel BEH 90 GL in the language / languages: English as an attachment in your email.

The manual is 10.47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Berbel BEH 90 GL

Berbel BEH 90 GL User Manual - German - 36 pages

Berbel BEH 90 GL User Manual - Dutch - 36 pages

Berbel BEH 90 GL User Manual - French - 36 pages

Berbel BEH 90 GL User Manual - Italian - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info