8.1.6 Null balance of the angle of inclination
- Place the device onto a plane surface and press the key
4
for > 5 seconds until the "Z"
symbol starts flashing on the digital display
2
.
- Press the key
4
again to store the "+SET" value.
- Turn the device by 180° and press the key
4
again to store the "-SET" value. The angle of
inclination has been balanced to null and the "Z" symbol is shown on the digital display.
- Press the key
4
again for > 5 seconds to exit the setting. The "Z" symbol disappears from
the LC display.
8.1.7 Compass bearing (orientation)
- Press the key
4
to display the angle of inclination and the compass bearing.
- The compass bearing is indicated continuously on the digital display
2
.
- To determine the cardinal direction, hold the device horizontally. As soon as the angle of
inclination exceeds +/- 20°, the compass bearing indication shows "- - -" and it is not possible
to take a bearing.
- Hold the marking
9
for the compass bearing in the direction which you would like to
determine. The direction is displayed in degrees:
0° = North, 90° = West, 180° = South, 270° = East
- Please observe that metallic objects or live conductors might affect the measuring accuracy
of the device.
insolation
angle of inclination
compass bearing
8.2 Data logger (measured value memory) with real-time clock
The BENNING SUN 2 can store up to 5000 data records consisting of the values for insola-
tion (solar irradiance), module temperature and ambient temperature. Each data record will be
provided with a time / date stamp. The measuring data can be read out via the integrated USB
interface and by means of a download software. The measuring interval (time between two
measurements) of the BENNING SUN 2 can be set from 1 minute to 60 minutes in increments
of one minute.
8.2.1 Data logger set-up
The set-up allows the user to set the measuring interval, the memory mode and to delete all
data records.
- Press the key
7
for > 5 seconds to call the data logger. "LOG" appears on the digital display
2
.
- Alternately, the display shows the occupied / free memory space as well as the battery
voltage / the measuring interval in minutes.
- To set the measuring interval (1 minute to 60 minutes), press the key
7
again for > 5
seconds. Display: "Int". Press the key
4
or key
5
to increase or decrease the value in
increments of one minute.
- Press the key
3
to display the memory mode. Display: "dAtA". Press the key
4
or key
5
to select "StOP" (if the memory is full) or "rOLL" (if you want to overwrite the oldest measured
values continuously).
- Press the key
3
again to delete the memory. Display: "dEL". Select "yES" or "nO" by
pressing the
4
or
5
keys to delete the entire memory.
- By means of the key
7
(OK), it is possible to store the setting at any time and to exit the data
logger.
- Press the key
3
or
4
to exit the data logger.
occupied memory
space
battery voltage
free memory space measuring interval
(1 min. to 60 min.)
alternating display
└──────────────┘
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning SUN 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning SUN 2 in the language / languages: English, German as an attachment in your email.

The manual is 2,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Benning SUN 2

Benning SUN 2 Quick start guide - English, German, Dutch, French, Italian, Spanish - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info