02/ 2011
BENNING ST 710
16
- If R
PE
is lower than the admissible limiting value, the measured value of R
PE
is shown and
a appears next to the R
PE
symbol. Now, the R
PE
measurement is carried out again with
reversed polarity. After the R
PE
test has been passed, the test of the insulating resistance is
started.
- If "Lo LOAD" is shown on the display, please check whether the test object is switched on.
-
Press the key
2
to continue the testing procedure in case of the load being too low (R
L-N
<100kΩ).
- If the insulating resistance R
ISO
is higher than the admissible limiting value, a appears
next to the R
ISO
symbol.
- Similarly, a is shown next to the I
EA
symbol, if the protective conductor current I
EA
is lower
than the admissible limiting value.
- The test is considered to be passed, if "PASS" is shown on the display.
Seegure3: TestingofdevicesofprotectionclassI(deviceswithprotectiveconductorand
accessible conductive parts which are connected to the protective conductor)
Note on measuring the protective conductor resistance:
- Alternatively, the measurement of the protective conductor resistance R
PE
can be car-
ried out as permanent measurement (max. 3 minutes). For this purpose press the key
2
for approx. > 5 sec. until the symbol appears on the display. Check the connecting
line of the test object by bending it over the entire length in order to detect weak points
or a break of the protective conductor. The BENNING ST 710 continuously records the
current measured value on the display and stores the maximum value in the memory. By
pressing the key
2
again, the measurement is carried out with reversed polarity. Press
the key again to indicate the maximum value of R
PE
on the display and to continue the
testing procedure as described in section 8.2.1.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning ST 710 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning ST 710 in the language / languages: English, German, Dutch, French, Polish, Swedish as an attachment in your email.

The manual is 7,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info