577296
10
Zoom out
Zoom in
Previous page
1/83
Next page
01/2014
DUSPOL
®
digital
10
- Fully grasp the display handle L2
9
and pass the detec-
tor
5
over a live line (e.g. a cable reel or a chain of lights)
from the feeding point (phase) in direction of the other end
of the line.
- As long as the line is not interrupted, the yellow LED Ω
M
for continuity is flashing.
- The point of the cable break has been localized as soon as
the yellow LED Ω
M
goes out.
Note:
The cable break detector may grounded power from 230 V,
50/60 Hz (phase to earth) are used. Insulating protective cloth-
ing and site conditions can affect the function.
12. Measuring point/display illumination (gure N)
- The measuring point illumination
4
can be switched on
with the probe tips being open by actuating the push-but-
ton
7
of the display handle L2
9
(1 second).
- The off automatically after 10 seconds
- The background lighting of the LC display
6
is activated
automatically by means of a light sensor
N
.
13. Battery replacement (gure O)
- Do not apply voltage to the device when the battery com-
partment is open!
- Please replace the batteries as soon as the
symbol
is shown on the LC display.
- The battery compartment is located on the back of the dis-
play handle L2/+
9
.
- Unscrew the screw of the battery compartment cover and
replace the used batteries by two new micro batteries
(LR03/AAA).
- Make sure that the new batteries are inserted with correct
polarity!
- Place the battery compartment cover onto the display
handle L2
9
and tighten the screw.
14. Technical data
- regulation: DIN EN 61243-3: 2011, IEC 61243-3: 2009
- nominal voltage range: 1 V to 1,000 V AC TRUE RMS/
1,200 V DC
- nominal frequency range f: 0 to 1000 Hz*
* according DIN EN 61243-3/IEC 61243-3, f: 16 ⅔ to 500 Hz
- voltage range: 6 V to 1,000 V AC TRUE RMS / 1,200 V DC
resolution 0.1 V (up to 198.9 V), 1 V (from 199 V on)
- voltage range < 6 V (low-volt): 1.0 V to 11.9 V AC / DC
resolution 0.1 V
- accuracy: ± 3 % of the measured value + 5 digits
- internal resistance of measuring circuit: 175 kΩ,
- current consumption of measuring circuit: I
S
< 7,2 mA
(1.200 V)
- current consumption of load circuit: I
S
< 550 mA (1,000 V)
- polarity indication: LCD symbol +/–
- phase and phase sequence indication: U
n
230 V,
50/60 Hz
- continuity test: 0 to 100 kΩ, LED + buzzer, testing current:
max. 10 μA
- diode test: 0.3 V to 2.0 V, testing current: max. 10 μA
- frequency range: 0 to 1,000 Hz
- accuracy: ± 3 % of the measured value + 2 digit
- resistance range: 0.1 to 300 kΩ, testing current: max.
10 μA
- accuracy: ± 5 % of the measured value + 5 digit
- cable break detector: ≥ U
n
230 V
- vibration motor, start: ≥ U
n
200 V
- overvoltage category: CAT IV 600 V,
CAT III 1,000 V
-
protection category: IP 65 (DIN VDE 0470-1 IEC/ EN 60529)
6 - first index: protection against access to dangerous
parts and protection against solid impurities, dustproof
5 - second index: protected against water jets. The device
can also be used in the rain.
-
max. allowable Duty cycle: 30 s (max. 30 seconds), 240 s off
- device switch-on by means of measuring voltage: ≥ 6 V, by
actuating the push-button
7
of the display handle L2/+
9
or by short-circuiting
the probe tips L1/-
2
and L2/+
3
- battery: 2 x micro, LR03/AAA (3 V)
- weight: approx. 250 g
- length of connecting cable: approx. 1,000 mm
- operating temperature and storage temperature range:
- 15 °C to + 55 °C (climatic category N)
- times of controlled reduction (thermal protection):
voltage/time: 230 V/30 s, 400 V/9 s, 690 V/5 s, 1000 V/2 s
- response time of the display: 1 s
15. General maintenance
Clean the exterior of the device with a clean dry cloth.
If there is contamination or deposits in the area of the battery
or the battery housing, clean these areas as well by means
of a dry cloth.
If the device is stored for a longer period of time, remove the
batteries from the device!
16. Environmental protection
Please lead the batteries and also the device at the
end of its useful life to the available return and col-
lection systems.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning Duspol Digital at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning Duspol Digital in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 14,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info