Before using the DUSPOL
®
digital voltage tester, proceed as
follows: Please read the operating manual and absolutely ob-
serve the safety instructions!
Table of Contents
1. Safety instructions
2. Device description
3. Functional test before use to ensure the absence of
voltage of an installation
4. Checking the absence of voltage of an installation
5. Load connection with vibration motor
6. External conductor test (phase indication)
7. Phase sequence test
8. Continuity test
9. Resistance measurement
10. Diode test
11. Cable break detector
12. Measuring point / display illumination
13. Battery replacement
14. Technical data
15. General maintenance
16. Environmental protection
1. Safety instructions:
- During the use, touch the tester at the isolated handles L1
8
and L2
9
only and do not touch the probe tips L1/-
2
and L2/+
3
!
- Check the voltage tester for correct functioning immedi-
ately before and after using it in order to ensure the ab-
sence of voltage of an installation (see section 3)! Do not
use the voltage tester, if one or more indications are not
working or if it does not seem to be ready for operation!
Please repeat the test with another voltage tester after-
wards.
- With the battery being exhausted, the voltage tester is not
fully functional! From a voltage of AC/DC ≥ 50 V on, volt-
age tests are also possible without batteries by means of
the LED step indicator
9
. The LC display
6
is activated
with a minimum voltage ≥ 90 V AC/DC.
- The voltage tester must be used only within the stated
nominal voltage range and in electrical installations of up
to 1,000 V AC / 1,200 V DC!
- The voltage tester must be used only in electric circuits of
overvoltage category CAT III with max. 1,000 V or over-
voltage category CAT IV with max. 600 V for phase-to-
earth measurements.
- Do not operate the device with the battery compartment
being open.
- The voltage tester is designed for being used by qualified
electricians and under safe working conditions.
- The LED step indicator
J
is intended for indicating the
voltage range. It is not intended for measuring purposes.
- Creating a voltage tester for more than 30 seconds volt-
age (maximum duty cycle = 30 s)!
- Do not dismantle the voltage tester!
- The voltage tester must be protected against contamina-
tion and damaging of the housing surface.
- To protect them against damaging, provide the probe tips
with the enclosed probe tip protector
1
after using the
voltage tester!
Electrical symbols on the device:
Symbol Meaning
Important documentation!
The symbol indicates that the guide described
in the manual, to avoid any risks
Device or equipment for working under voltage
Push-button
Alternating voltage (AC)
Direct voltage (DC)
Direct and alternating voltage (DC/AC)
Earth (voltage to ground)
Phase sequence indication; the phase se-
quence can be indicated only at 50 or 60 Hz
and in an earthed mains
This symbol shows the orientation of the batter-
ies for inserting them with correct polarity
2. Device description
1
Probe tip protector
2
Probe tip L1/-
3
Probe tip L2/+
4
LED measuring point illumination
5
Sensor of the cable break detector
6
LC display
7
Push-button
8
Handle L1
9
Display handle L2
J
LED step indicator
K
Red LED for external conductor test (phase indication)
L
Green LEDs ◄LR► of the phase sequence indication
(left/right)
M
Yellow LED Ω for continuity test (lights up)/cable break
detector (ashes)
N
Light sensor for LC display illumination
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning Duspol Digital at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning Duspol Digital in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 14,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info