577174
15
Zoom out
Zoom in
Previous page
1/97
Next page
09/ 2013
BENNING CM 1-1/ 1-2
9
2. Safety instructions
The instrument is built and tested in accordance with
DIN VDE 0411 Teil 1/ EN 61010-1
and has left the factory in perfectly safe technical condition.
To preserve this condition and to ensure safe operation of the device, the user
must observe the notes and warnings given in these instructions at all times.
The BENNING CM 1‑1/ 1‑2 must be used in electrical circuits
of overvoltage category III with a conductor for a maximum of
600 V to earth only.
Only use suitable measuring leads for this. With measure
ments within measurement category III, the projecting conduc‑
tive part of a contact tip of the measuring leads must not be
longer than 4 mm.
Prior to carrying out measurements within measurement cat
egory III, the push‑on caps provided with the set and marked
with CAT III and CAT IV must be pushed onto the contact tips.
The purpose of this measure is user protection.
Please observe that work on live parts and electrical compo
nents of all kinds is dangerous! Even low voltages of 30 V AC
and 60 V DC may be dangerous to human life.
Before starting the current clamp multimeter, always check the
device as well as all measuring leads for damages.
If it can be assumed that safe operation is no longer possible, switch the device
off immediately and secure it against unintended operation.
Safe operation can be assumed to be no longer possible, if
- the device or the measuring leads exhibit visible damages,
- the device no longer works,
- the device has been stored under unfavourable conditions for a longer pe-
riod of time,
- the device was exposed to extraordinary stress during transport.
In order to prevent danger
do not touch the bare measuring probe tips of the
measuring leads,
insert the measuring leads into the respectively designated
measuring sockets of the multimeter.
3. Scope of delivery
The scope of delivery of the BENNING CM 1-1/ 1-2 comprises:
3.1 One BENNING CM 1-1/ 1-2,
3.2 One safety measuring leads, red (L = 1.4 m), ( BENNING CM 1-2)
3.3 One safety measuring leads, black (L = 1.4 m), ( BENNING CM 1-2)
3.4 One compact protective pouch,
3.5 One 9 V block battery for initial assembly is integrated into the device
(BENNING CM 1-1)
Two 1.5 V micro (AAA) batteries for initial assembly are integrated into
the device ( BENNING CM 1-2)
3.6 One operating manual.
Parts subject to wear:
- The BENNING CM 1-1 is supplied by means of an integrated 9 V block bat-
tery (IEC 6 LR 61).
- The BENNING CM 1-2 is supplied by means of two integrated 1.5 V micro
(AAA) batteries (IEC LR 03).
- The safety measuring leads mentioned above (tested accessories) comply
with CAT III 1000 V and are approved for a current of 10 A.
4. Device description
See gure 1a, 1b: Device front
The display and operating elements shown in gures 1a and 1b are designated
as follows:
1
Digital display, displaying measured value and range exceedance
2
Polarity indication,
3
Battery indication, appears in case of discharged battery,
4
HOLD key, storage of the displayed measured value,
5
MAX key, storage of the highest measured value,
6
Key (change‑over), for selecting AC voltage/ DC voltage or resistance
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Benning CM1.1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Benning CM1.1 in the language / languages: English, German, Dutch, French, Italian, Polish, Swedish, Turkish, Spanish as an attachment in your email.

The manual is 4,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info