Next page
7
Permitted natural gas connections itemised according to
countries:
Liquid gas connection (LPG)
Caution!
Follow country-specific guidelines.
If liquid gas (LPG) is used, the gas connection is established
via a gas hose or a fixed connection.
If a gas hose is used, pay attention to the following measures:
Use a safety hose or plastic hose (8 mm diameter).
Secure it to the gas connection with a connecting device (e.g.
a hose clamp).
The hose must be short and fully leakproof. The hose must
not be longer than 1.5 m. Pay attention to current guidelines.
The gas hose must be replaced annually.
Insert the safety hose and tighten using a screw coupling or
hose clamp.
Carry out a leak test once connection is complete. See the
section entitled "Leak test".
Conversion to a different gas type
Measures to note
The appliance may only be converted to a different gas type
by an approved specialist, in accordance with the
instructions in this manual.
Incorrect connection and incorrect settings may cause
serious damage to the appliance. The appliance
manufacturer accepts no liability for damage and
malfunctions of this kind.
Pay close attention to the symbols indicated on the rating plate.
If there is no symbol for your country, follow the technical
guidelines that apply in your country when making settings.
Before setting up the appliance, determine the gas type and
pressure in the local supply network. Before using the
appliance for the first time, make sure that all settings have
been made correctly.
Pay attention to local and international rules and regulations.
All connection data can be found on the rating plate on the rear
of the appliance at the bottom.
Enter the data in the following table:
Product number (E no.),
Manufacturing number (FD),
Enter the factory settings for gas type/gas pressure, as well as
the settings for gas type/pressure that apply after the gas
conversion, in the following table.
The changes made to the appliance and the type of connection
play an important role in ensuring that the appliance operates
correctly and safely.
Converting to a different gas type
The gas connection must be replaced.
The nozzles for the burners must be replaced.
Depending on the factory gas setting, the bypass nozzles in
the burner valves must either be replaced, or screwed in fully.
Numbers are printed on the nozzles indicating their diameter.
Further information about the gas types suitable for the
appliance, as well as the corresponding gas nozzles, can be
found in the section entitled "Technical properties - gas".
After the conversion
After the appliance has been converted to a different gas
type, you must perform a leak test. See the section entitled
"Leak test".
After the appliance has been converted to a different gas
type, you must check the flame behaviour. See the section
entitled "Correct flame behaviour".
Country
EN 10226 R
^
(TS 61-210 EN
10226 R
^)
EN ISO 228
G
^
(TS EN ISO
228 G
^)
AT Austria X
BE Belgium X
CH Switzerland X
DE Germany X
ES Spain X X
FR France X
GR Greece X
IT Italy X X
NL Netherlands/Holland X
PT Portugal X X
HR Croatia X
SL Slovenia X
YU Serbia X
TR Turkey X X
PL Poland X X
RO Romania X X
AE United Arab Emirates X
ZA South Africa X
HU Hungary X
RU Russia X
GB United Kingdom X
/3***
E no. FD no.
After-sales service
O
Type of gas / gas pressure
Data on the rating plate
Type of gas / gas pressure
Data after gas conversion
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Belion GK604ZB10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Belion GK604ZB10 in the language / languages: English, Dutch as an attachment in your email.

The manual is 1,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Belion GK604ZB10

Belion GK604ZB10 User Manual - English, Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info