Short Seam Automat 2211-5 Working InstructionsBeisler Automated Sewing Equipment
C.3
Start-up
C.3.2 Compressed air / vacuum connections
Fig. 3: The compressed air connection is preinstalled on
the machine. It comprises the following components:
Pressure reducer
3
with manometer
5
and water
separator
4
,
Pressure hose with push-in plug
1
.
The pressure reducer is installed at the side mounting wall
of the worktable.
Connecting the machine to the compressed air sup-
ply system:
1. Connect pressure hose plug to on-site terminal unit.
2. Open on-site compressed air supply.
3. Fig. 3: Set pressure reducer to a machine operating
pressure of 6 bar by rotating pressure reducer knob
1
and read value on manometer
5
:
• To increase pressure, rotate in clockwise direction.
• To reduce pressure, rotate in counter-clockwise di-
rection.
Connecting the machine to the vacuum supply sy-
stem:
Fig. 4: If the machine is equipped with the optional vacuum
pump
3
, no further installation is required. The vacuum
system is ready for operation.
If the machine is delivered without vacuum pump, the on-
site vacuum source must be connected to the machine's
vacuum valve. The vacuum valve
5
is mounted below
the worktable.
NOTE - Required components!
The following components are required on the site:
A vacuum hose 3 with an inner diameter of at least
1¼ '' or, as required, an adapter or reducing fitting
to accommodate the on-site vacuum hose on the
sleeve (outer diameter 1¼ '') of the machine's vacu-
um valve.
A hose clamp with an inner diameter of at least
1¼ ''.
1. Fig. 4: Connect the on-site vacuum hose to the con-
nection sleeve
4
of the vacuum valve
5
.
2. Attach vacuum hose using the hose clamp.
3. Make sure that the vacuum hose
1
to the table pla-
te has been attached correctly and securely.
4. Open on-site vacuum source.
Fig. 3/4
Fig. 3
Fig. 4
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Beisler 2211-5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Beisler 2211-5 in the language / languages: English as an attachment in your email.

The manual is 8,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Beisler 2211-5

Beisler 2211-5 User Manual - German - 103 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info