WARNING
WARNING
WARNING
WARNING
Instruction Manual Junior II
11
3. LOCATION, OPERATION, BOTTLE FILLING
LOCATION
Never operate the compressor in
potentially explosive atmosphere!
Keep unit away (min. 2m) from in
flammable items. Do not smoke
while petrol tank is open and while
unit is in operation.
Outdoor location
The compressor unit is not seawater resis
tant. At operation in salty air spray com
pressor with anticorrosive protection (e. g.
Quicksilver Corrosion Guard). Electric
driven units should be operated and stored
below deck. Units with petrol engine should also be
stored below deck after the filling process.
- Locate the unit level.
- On units with petrol engine it is most important that only
clean air be used, position compressor in direction of
wind so that exhaust fumes are blown away from the
unit. Please use the provided telescopic intake tube. See
Fig. 7 and chapter 4.4.2. This arrangement will ensure
necessary spacing between exhaust outlet and air inlet.
Fig. 7 Outdoor location
WIND
Exhaust
- Turn unit as soon as wind direction changes.
- Take care that no vehicles are in direct vicinity with en
gines running.
- Do not operate unit in the vicinity of open fire (flue gas!).
Indoor location
Petrol driven units must not be oper
ated indoors.
- Ensure adequate ventilation.
- Here too, air must be free from exhaust fumes and haz
ardous vapours (e.g. smoke, solvent vapours, etc.).
- If possible install unit in such a manner that the com
pressor fan can get fresh air from outside, for instance
through an opening in the wall.
- Ensure that an adequate exhaust air opening is provided.
- When locating the compressor in small rooms where
natural ventilation is not ensured, measures must be
taken to provide artificial ventilation (this also applies
when other systems having high radiation are operating
in the same room).
Electrical installation
For installation of electrical equipment observe the follow
ing:
- Comply with regulations of local electricity supply com
pany.
- Arrange for the electrics to be connected by an electri
cian only.
- Ensure correct installation of protective conductor.
- Check conformity of motor tension and frequency with
those of electric network.
- Operate electric units only on mains sockets equipped
with fault current circuit breaker according to DIN VDE
0664 with a nominal differential current of less than 30
mA (up to 16 A in single-phase AC circuits).
- For units not connected through a plug, but permanently
installed, a main switch must be provided which has a
contact gap of minimum 3 mm on each pole.
- Fuse motor correctly; use slow-blow fuses, only.
- Immediately after start-up check direction of rotation for
agreement with arrow on unit.
If power supply cable is to be replaced, use
cable of same type, only!
- When using extension leads or cable drums, operate unit
with unwound cable, only to avoid overheating and risk
of fire. The maximum length for extension cables at nor
mal ambient temperatures (approx. 20 C) is 25 metres.
The power plug must be easily
accessible and separable to shut
down quickly the unit in case of
emergency.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bauer Junior II at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bauer Junior II in the language / languages: English as an attachment in your email.

The manual is 1,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bauer Junior II

Bauer Junior II User Manual - German - 58 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info